Eiki EIP-X350 owner manual EN-28

Page 29

1.Turn off the projector.

2.Allow the projector to cool for at least 45 minutes.

3.Unplug the power cord.

4.Loosen the screws in the lamp cover 1 and remove the cover 2 .

5.Remove the screws from the lamp module 3 , raise the handle 4 , and lift out the module 5 .

6.Insert the new lamp module into the projector and tighten the screws.

7.Replace the lamp cover and tighten the screws.

8.Turn on the projector. If the lamp does not turn on after the warm-up period, try reinstalling the lamp.

9.Reset the lamp timer. Press MENU, go to Setup > Advanced setup > Reset lamp hours, and press MENU.

„Dispose of the used lamp according to local regulations.

„Ensure that screws are tightened properly. Screws not tightened fully may result in injury or accidents.

„Since the lamp is made of glass, do not drop the unit and do not scratch

the glass.

„ Do not reuse the old lamp. This could cause the lamp to explode.

„Be sure to turn off the projector and unplug the AC power cord before replacing the lamp.

„Do not use the projector with the lamp cover removed.

EN-28

Image 29
Contents Model EIP-X350 EN-1 Federal Communication Commission NoticeEN-2 Safety InstructionsEN-3 EN-4 Contents EN-6 Projector FeaturesIntroduction Package Contents EN-8 Projector OverviewFront View EN-9 Rear ViewBottom View EN-10 Using the ProductControl Panel EN-11 TerminalsEN-12 Remote ControlEN-13 Installing the BatteriesEN-14 EN-15 Remote Control OperationEN-16 InstallationConnecting the Projector Powering on the projector Powering On/Off the ProjectorPowering Off the Projector EN-17EN-18 Adjusting the ProjectorAdjusting the Projector Height EN-19 Adjusting the Projector Zoom and FocusEN-20 Adjusting Projection Image SizeEN-21 How to operateMenu Operation EN-22 Setup MenuEN-23 Picture MenuEN-24 EN-25 Source Menu Help Menu Cleaning the Lens MaintenanceCleaning the Projector Housing EN-26EN-27 Replacing the LampEN-28 EN-29 SpecificationsIndicators Projector Condition Power LED Indicator MessagesAppendix EN-30Compatibility Modes Compatibility Resolution Sync KHz Sync HzComputer VideoEN-32 TroubleshootingEN-33 Press MENU, go to Picture VGA settings,Adjust Frequency or Tracking Deutschland & Österreich