PICTURE IMAGE

Color temp.

Press either POINT LEFT button or POINT RIGHT button to Color temp. level that you want to select. (XLow, Low, Mid or High)

White balance (Red)

Press POINT LEFT button to lighten red tone and POINT RIGHT button to deeper tone. (From 0 to 63.)

White balance (Green)

Press POINT LEFT button to lighten green tone and POINT RIGHT button to deeper tone. (From 0 to 63.)

White balance (Blue)

Press POINT LEFT button to lighten blue tone and POINT RIGHT button to deeper tone. (From 0 to 63.)

Sharpness

Press POINT LEFT button to soften the image, and POINT RIGHT button to sharpen the image. (From 0 to 31.)

Gamma

Press either POINT LEFT button or POINT RIGHT button to obtain better balance of contrast. (From 0 to 15.)

Noise reduction

Press POINT LEFT/RIGHT button(s) to change noise reduction mode. Dialog box display is changed to “On” to reduce noise (rough parts) of image. Press POINT LEFT/RIGHT button(s) again, to change noise reduction mode to off.

Progressive scan

Press POINT LEFT/RIGHT button(s) to change progressive scan mode. Dialog box display is changed to “Off”, “L1”, “L2”.

Off ··· Progressive scan mode to OFF.

L1 ···· Progressive scan mode to ON (for active picture).

L2 ···· Progressive scan mode to ON (for still picture).

Store

To store manually preset image, move a red frame pointer to Store icon and press SELECT button. Image Level Menu will appear. Move a red frame pointer to Image 1 to 4 where you want to set and then press SELECT button.

Other icons operates as follows.

Reset

Reset all adjustment to previous figure.

Quit

Closes IMAGE MENU.

Press SELECT button at this icon to display other items.

Press SELECT button at this icon to display previous items.

Press POINT LEFT/RIGHT buttons to adjust value.

Image Level Menu

Move a red frame pointer to any of Image 1 to 4 where you want to set and then press SELECT button.

Store icon

Press SELECT button at this icon to store the adjustment.

NOTE :

Tint cannot be adjusted when the video system is PAL, SECAM, PAL-M or PAL-N.

Progressive cannot be operated when “480p”, “575p” or “720p” is selected on AV SYSTEM MENU (P31).

36

Image 36
Contents Model LC-X60 Multimedia ProjectorTo the Owner Safety Instructions Voor de klanten in NederlandCompliances Esperanza Rancho Santa Margarita CATable of Contents Features and Design Compact Design Digital Zoom for ComputerPreparation Name of Each Part of ProjectorHOT AIR Exhausted SETTING-UP Projector Connecting AC Power CordFor U.S.A. and Canada For Continental Europe Preparation Positioning Projector Room LightPreparation Adjustable Feet Installing Projector in Proper PositionPreparation Moving Projector Connecting Projector Terminals of ProjectorConnect computer output Digital DVI-D type to this terminal Refer to P13Connecting to Computer TerminalsA Projector Front of the projector Audio Input External Audio Equipment Audio SpeakerConnecting to Video Equipment A ProjectorOperation of Remote Control Inside the Battery Compartment BOXBefore Operation Laser Pointer FunctionPoint Volume + Buttons Timer ButtonZoom Button Select ButtonTOP Controls and Indicators Point Volume + / ButtonsHOW to Operate ON-SCREEN Menu Operating ON-SCREEN MenuFlow of ON-SCREEN Menu Operation Press Menu Button while connecting to PC input source Used to adjust picture imageBefore Operation Menu BAR Used to selectBasic Operation Turning on / OFF ProjectorTurning on Projector Turning OFF ProjectorAdjusting Screen Keystone AdjustmentFocus adjustment may not function properly if the image is Corrected by Keystone adjustmentSound Adjustment Computer Input Selecting Input SourceSelecting Computer System Rgbav HdcpAutomatic MULTI-SCAN System AutoPC System Menu PC Adjustment Auto PC AdjustmentPC Adjust Menu Auto PC AdjComputer Input Manual PC Adjustment Display area Display area HFull screen Picture Image Select Image Level Select DirectImage Level Select Menu Image 1~4Picture Screen Adjustment Screen MenuWhen video input signal is connected to Y-Pb/Cb Video InputVideo Select VideoComponent Video Signal Format Selecting Video SystemPAL / Secam / Ntsc / NTSC4.43 / PAL-M / PAL-N AV System Menu Video or S-VIDEOPicture level adjusted for picture with fine tone CinemaProvides image at a normal video aspect ratio of 4 Provides image at a wide screen ratio of 16Picture Image Adjustments Image Adjust MenuPicture Image List Mode Picture ImageColor temp White balance RedWhite balance Green White balance BlueSetting Setting MenuSetting Menu Anamorphic Blue backDisplay Menu positionTo change the code of the Remote Control Unit Power managementRemote control To change the code of ProjectorWireless Mouse mode Projector modeUSB Operating Wireless Mouse InstallationOperating Wireless Mouse AppendixMaintenance Section AIR Filter Care and Cleaning on nextIndicatorIndicator Projector so that Ventilation Slots are not obstructedAppendix AIR Filter Care and Cleaning Cleaning Projection LensRecommendation Pull up and removeLamp Replacement Lamp ReplaceMessage Lamp replace counter reset? is displayed. Move Reset Lamp Replace CounterAppendix Lamp Replace Counter Pointer to Yes and then press Select buttonTroubleshooting Remote Control Unit Wireless MouseDoes not work Function does notAppendix Indicators and Projector Condition Appendix Compatible Computer Specifications ResolutionMenu Tree PC sourceSystem Setting Sound Technical Specifications Appendix Configurations of Terminals Control Port ConnectorUSB Connector Series B Computer INPUT-1 and Monitor OUT Terminals AnalogLens Replacement Appendix Optional PartsAppendix Key to better communications Canada