Eiki LC-XG100, LC-XG200 Before Operation, Operation of Remote Control, Laser Pointer Function

Page 14

BEFORE OPERATION

OPERATION OF REMOTE CONTROL

Left Side

ON

ALL OFF

ALL-OFF SWITCH

When using Remote Control Unit, turn this switch to “ON.” And turn it to “ALL OFF” when it is not used.

INSIDE THE BATTERY COMPARTMENT BOX

This remote control provide the DIP switches into the battery compartment box.

Slide the SW4 (LASER ON/OFF switch) to "OFF" position. The laser pointer function is not operated.

Set switches 1-3 as shown in table below depending on Code No. that you want to select remote control code.

(Refer to P37.)

DIP SWITCH SETTING

 

 

 

 

 

 

 

SW4 ........ LASER ON/OFF

 

 

 

 

 

 

 

SW1

SW2

SW3

Code No.

 

 

 

 

4

 

ON

ON

ON

Code 1

 

 

 

 

 

 

 

ON

 

 

 

3

 

ON

ON

OFF

Code 2

 

 

 

2

 

ON

OFF

ON

Code 3

 

 

 

 

 

 

 

ON

OFF

OFF

Code 4

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

OFF

ON

ON

Code 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

ON

OFF

Code 6

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

OFF

ON

Code 7

 

 

 

 

 

 

 

OFF

OFF

OFF

Code 8

LASER POINTER (Drag ON)

INDICATOR

Lights red while laser beam is emitted from Laser Light Window.

Lights green when drag ON position. (P40)

MUTE BUTTON

Used to mute sound. (P21)

DRAG ON/OFF BUTTON

Used to select drag ON/OFF position. (P40)

LEFT CLICK BUTTON

Used as a PC mouse in Wireless Mouse Operation. Press this button and the mouse pointer button to drag

aselected screen object. (P40)

LASER BUTTON

Used to operate Laser Pointer Function. Laser beam is emitted while pressing this button within 1 minute.

When using this Laser Pointer for more than 1 minute, release LASER button and press it again.

FOCUS BUTTON

Used to adjust focus. (P20)

 

 

AUTO PC ON-OFF

 

D.ZOOM FREEZE NO SHOW

LOCK

MUTE

IMAGE

VOLUME-

SELECT VOLUME+

 

 

MENU

KEYSTONE

LASER

P-TIMERCOMPUTER 1

ZOOM

COMPUTER 2

VIDEO

FOCUS LENS

POWER ON-OFF BUTTON

Used to turn projector on or off. (P19)

AUTO PC ADJ. BUTTON

Use to operate AUTO PC Adjustment function. (P25)

IMAGE BUTTON

Used to select image level. (P28, 33)

KEYSTONE BUTTON

Used to correct keystone distortion. (P20, 36)

MOUSE POINTER

Used as a PC mouse in Wireless Mouse Operation. (P40)

RIGHT CLICK BUTTON

Used as a PC mouse in Wireless Mouse Operation. (P40)

LENS SHIFT BUTTON

Used to select LENS SHIFT function. (P20)

LASER POINTER FUNCTION

This Remote Control Unit emits a laser beam as laser pointer function from Laser Light Window. When LASER button is pressed, laser light goes on. And when LASER button is being pressed for more than 1 minute or LASER button is released, light goes off. LASER POINTER INDICATOR lights RED and Laser is emitted with RED light to indicate laser beam is being emitted.

Laser emitted is a class II laser; therefore, do not look into Laser Light Window or shine laser beam on yourself or other people. Three marks below are caution labels for laser beam.

CAUTION : Use of controls, adjustments or performance of procedures other than those specified herein may result hazardous radiation exposure.

These caution labels are put on remote control.

LASER POINTER INDICATOR

Laser Light Window

14

Image 14
Contents Model LC-XG100 Multimedia ProjectorTo the Owner Safety Instructions Voor de klanten in NederlandCompliances Federal Communication Commission NoticeTable of Contents Features and Design Compact DesignHOT AIR Exhausted PreparationName of Each Part of Projector For U.S.A. and Canada For Continental Europe SETTING-UP ProjectorConnecting AC Power Cord Preparation Positioning Projector Room LightPreparation Adjustable Feet Moving ProjectorTerminals of Projector Connecting ProjectorUSB Connector Series B Monitor OutputTerminals Connecting to ComputerConnecting Projector ProjectorAudio Video Connecting to Video EquipmentTerminals Projector Before Operation Operation of Remote ControlInside the Battery Compartment BOX Laser Pointer FunctionZoom Button Point Volume + ButtonsTimer Button Select ButtonTOP Controls and Indicators Lamp Replace IndicatorFlow of ON-SCREEN Menu Operation HOW to Operate ON-SCREEN MenuOperating ON-SCREEN Menu Sound Menu Before Operation Menu BARGuide Window Turning on Projector Basic OperationTurning on / OFF Projector Turning OFF ProjectorFocus Adjustment Adjusting ScreenZoom Adjustment Lens Shift AdjustmentSound Adjustment RGB Computer InputSelecting Input Source PC System Menu Selecting Computer SystemAuto XGA Computer Input Compatible Computer SpecificationsResolution PC Adjust Menu PC AdjustmentAuto PC Adjustment Auto PC AdjComputer Input Manual PC Adjustment Full screen Display areaDisplay area H Image Level Select Menu Picture Image AdjustmentsImage Level Select Direct Image 1~4Computer Input Image Level Adjustment Image Adjust MenuPicture Screen Adjustment Screen MenuVideo Video InputVideo PAL / Secam / Ntsc / NTSC4.43 / PAL-M / PAL-N Component Video Signal FormatSelecting Video System AV System Menu Video or S-VIDEOCinema Video Input Image Level Adjustment Provides image at a normal video aspect ratio of 4 Setting Menu SettingSetting Menu To change the code of the Remote Control Unit To change the code of ProjectorLamp Replace Lamp ReplacementAppendix Lamp Handling Precautions Appendix Lamp Replace CounterOperating Wireless Mouse Operating Wireless MouseInstallation Cleaning Projection Lens MaintenanceAIR Filter Care and Cleaning RecommendationTroubleshooting Does not work Remote Control UnitWireless Mouse Function does notTechnical Specifications USB Connector Series B Appendix Configurations of TerminalsControl Port Connector Computer INPUT-1 and Monitor OUT Terminals AnalogPOA-MCMAC Optional PartsPOA-MCPS2 POA-MACAPPage Key to better communications Canada