Specifications
This section lists certain specifications for your computer. For the latest specification information, see the User Guide for your computer model and type at:
http://www.ibm.com/pc/support/
Dimensions
Width: 12.2 inches (310 mm)
Height: 3.35 inches (85 mm)
Depth: 14.1 inches (358 mm)
Weight
Minimum configuration as shipped: 7.3 kg (16 lbs)
Maximum configuration: 8.5 kg (18.7 lbs)
Environment
Air temperature:
Operating at 0 - 3000 ft (914.4 m): 10° to 35°C (50° to 95°F)
Operating at 3000 ft - 7000 ft (2134 m): 10° to 32°C (50° to 89.6°F)
Humidity:
Operating: 8% to 80%
Transit: 8% to 90%
Maximum altitude: 7000 ft (2133.6 m)
Electrical input
Input voltage:
Low range:
Minimum: 100 V ac
Maximum: 127 V ac
Input frequency range:
Voltage switch setting: 115 V ac
High range:
Minimum: 200 V ac
Maximum: 240V ac
Input frequency range:
Voltage switch setting: 230 V ac
Input
Minimum configuration as shipped: 0.09 kVA
Maximum configuration: 0.23 kVA
Heat output (approximate) in British thermal units (Btu) per hour:
Minimum configuration: 205.8 Btu/hr (60 watts)
Maximum configuration: 548.8 Btu/hr (160 watts)
Airflow
Approximately 14 cubic feet (0.45 cubic meters) per minute
Acoustical noise-emission values
Note: In this computer, fan speed is controlled by temperature, configuration, and software. Actual
Average
At operator position - 0.5 meters:
Idle: 30 dBA
Operating: 34 dBA
At bystander position - 1 meter (3.3 ft):
Idle: 26 dBA
Operating: 29 dBA
Declared (upper limit)
Idle: 4.0 bels
Operating: 4.3 bels
Average
At operator position - 0.5 meters:
Idle: 31 dBA
Operating: 34 dBA
At bystander position - 1 meter (3.3 ft):
Idle: 26 dBA
Operating: 29 dBA
Declared (upper limit)
Idle: 4.0 bels
Operating: 4.3 bels
Note: These levels were measured in controlled acoustical environments according to the procedures specified by the American National Standards Institute (ANSI) S12.10 and ISO 7779 and are reported in accordance with ISO 9296. Actual