Hitachi CP-X885 user manual Regarding the Indicator Lamps, Power Lamp Temp

Page 9

Regarding the Indicator Lamps

Lighting and flashing of the POWER indicator, the LAMP indicator, and the TEMP indicator have the meanings as described in the Table below. Please respond in accordance with the instructions within the Table.

POWER

LAMP

TEMP

Description

indicator

indicator

indicator

 

 

 

 

 

The orange

Turned OFF

Turned OFF

The STANDBY mode is set

lamp is lighted

(Not lighted)

(Not lighted)

 

 

 

 

 

Flashing of the green lamp

Turned OFF

Turned OFF

The unit is warming up. Please wait.

 

 

 

 

The green lamp is lighted

Turned OFF

Turned OFF

The unit is in an ON state. Ordinary operations may be performed.

 

 

 

 

Flashing of the orange lamp

Turned OFF

Turned OFF

The unit is cooling down. Please wait.

 

 

 

 

 

 

 

The unit is cooling down. Please wait.

Blinking of the

-

-

A certain error has been detected. Wait until the POWER indicator lamp has finished

red lamp

flashing, and then perform the proper response measure using the item descriptions

 

 

 

 

 

below as reference.

 

 

 

 

 

 

 

The lamp does not light.

The red lamp

The red lamp

Turned

There is a possibility that the interior portion has become heated. Turn the power OFF and wait

is lighted, or

approximately 20 minutes. After the main unit has cooled down, please confirm whether or not

is lighted

OFF

there is blockage of the air passage aperture, whether or not the filter is dirty, and/or whether or

blinks

 

 

not the peripheral temperature exceeds 35°C, etc. After performing any needed maintenance,

 

 

 

turn the power ON again; if the same display is displayed, then please change the lamp.

 

 

 

 

The red lamp

 

 

Either there is no lamp and/or lamp cover, or either of these has not been properly fixed

Blinking of the

Turned

(attached). Turn the power OFF and wait approximately 45 minutes. After the main unit has

is lighted, or

sufficiently cooled down, please make confirmation of the attachment state of the lamp and

red lamp

OFF

blinks

lamp cover. After performing any needed maintenance, turn the power ON again; if the same

 

 

 

 

 

display is displayed, then please contact a sales store or a service company.

 

 

 

 

The red lamp

Turned

Blinking of the

The cooling fan is not operating. Turn the power OFF and wait approximately 20 minutes. After the

is lighted, or

main unit has cooled down, please make confirmation that no foreign matter has become caught in

OFF

red lamp

the fan, etc. After performing any needed maintenance, turn the power ON again; if the same display

blinks

 

 

is displayed, then please contact a sales store or a service company.

 

 

 

 

 

 

 

There is a possibility that the interior portion has become heated. Turn the power OFF and wait

The red lamp is

Turned

The red lamp is

approximately 20 minutes. After the main unit has cooled down, please confirm whether or not

lighted, or

there is blockage of the air passage aperture, whether or not the filter is dirty, and/or whether or

OFF

lighted

not the peripheral temperature exceeds 35°C, etc. After performing any needed maintenance,

blinks

 

 

turn the power ON again; if the same display is displayed, then please contact a sales store or a

 

 

 

service company.

The green lamp

Alternative blinking

There is a possibility that the interior portion has become overcooled. Please use the unit within

the usage temperature parameters (0°C to 35°C). After performing any needed maintenance,

is lighted

with the red lamp

turn the power ON again; if the same display is displayed, then please contact a sales store or a

 

 

 

service company.

The green

Simultaneous blinking

This is a notification that it is time to clean the filter.

After cleaning the filter, operate the FILTER TIME portion of the OPTION Menu, and perform

lamp is lighted

with the red lamp

reset of the FILTER TIME.

 

 

 

 

 

 

 

NOTE

When the interior portion has become overheated, for safety purposes, the power source is automatically turned OFF, and the indicator lamps may also be turned OFF. Press the “ ” (power OFF) side of the main power switch, and wait for approximately 20 minutes. Please then use the unit only after having first confirmed that the unit has sufficiently cooled down.

9

Image 9
Contents Contents Main Menu Multifunctional SettingsMain Menu Item selectionPICTURE-2 Menu PICTURE-1 MenuPICTURE-1 Menu PICTURE-2 MenuInput Menu Input MenuAuto Menu Auto MenuScreen Menu Screen MenuWireless Menu Option MenuOption Menu Related Messages Power Lamp Temp Regarding the Indicator LampsPhenomena That May Easily Be Mistaken for Machine Defects PhenomenonItems to be confirmed Specifications Dimension DiagramSpecification Warranty and AFTER-SERVICE Signal Connector PIN Assignment Signal Terminal SpecificationMini Din 4-pin Resolution FH kHz FV Hz Rating Signal mode Display mode Example of Computer SignalInitial SET Signals ADB Mouse Connection to the Mouse ControlUSB Mouse PS/2 MouseRS-232C Communication Command dataProtocol HeaderChanging the projector settings Set command Requesting projector status Get commandUsing the projector default settings Reset Command Increasing the projector setting value Increment commandC4 D3 Command data chartBe EF BA D2 Be EF AD D0 Be EF CB D0 Hitachi Sales Europe GmbH Hitachi Europe GmbHHitachi Business Systems Nordic Hitachi France

CP-X885 specifications

The Hitachi CP-X885 is a versatile and high-performance projector designed to meet the demands of various settings, including classrooms, conference rooms, and auditoriums. Known for its reliability and image quality, the CP-X885 stands out in the competitive projector market by integrating advanced technologies that enhance both functionality and usability.

One of the main features of the CP-X885 is its impressive brightness, boasting a luminous output of 3800 ANSI lumens. This ensures vivid and clear images even in well-lit environments, making it ideal for presentations and educational purposes. The projector also offers a high contrast ratio of 2000:1, which contributes to sharp and detailed visuals, allowing text and graphics to stand out distinctly.

In terms of resolution, the Hitachi CP-X885 supports XGA (1024x768), a standard that provides clarity and detail, particularly suited for presentations that involve text-heavy content. The projector supports a variety of video signals, from composite to component video, making it highly versatile for different input sources.

The CP-X885 incorporates advanced optical technology, including a 1.2x optical zoom lens that allows for flexible installation options. This feature enables users to adjust the image size without needing to reposition the projector, providing convenience for quick setups. Additionally, its vertical and horizontal keystone correction ensures that images remain properly aligned, even when projected from an angle.

Another notable aspect of the CP-X885 is its long lamp life, rated at up to 5000 hours in standard mode and 6000 hours in eco mode. This longevity translates to reduced maintenance costs and less frequent lamp replacements, allowing for uninterrupted usage. The projector is also equipped with a quiet operation mode, with noise levels as low as 29 dB, creating an unobtrusive viewing experience.

For connectivity, the CP-X885 offers multiple options, including HDMI, VGA, and USB ports. This flexibility allows users to connect various devices such as laptops, media players, and document cameras easily. Network capabilities are also supported, allowing for remote control and monitoring of the projector, which is advantageous for IT administrators in educational and corporate environments.

In summary, the Hitachi CP-X885 combines brightness, clarity, and user-friendly features, making it a reliable choice for anyone in need of a high-quality projector. Its robust design, coupled with versatile connectivity options and maintenance-friendly attributes, ensures that it meets the dynamic requirements of modern presentations and educational needs.