NEC XEN IPK setup guide IAD 8-U ETU WEB

Page 8

June 2004

NEC Business Solutions Ltd

 

 

S E C T I O N 3

IAD (8)-U( ) ETU WEB

PROGRAMMING

When installed for the first time, the IAD (8)-U( ) ETU, comes up with factory set default parameters as shown in Table D-2 Factory Network Settings.

Table D-2 Factory Network Settings

 

 

 

 

 

 

Host Name

 

neciad

 

 

 

 

 

 

 

 

 

 

 

 

IP Address

 

192.168.1.100

 

 

 

 

 

 

 

 

 

 

 

 

Subnet Mask

 

255.255.255.0

 

 

 

 

 

 

 

 

 

 

 

 

Default Gateway

 

192.168.1.1

 

 

 

 

 

 

 

 

 

 

 

In this configuration, the ETU cannot run in any randomly given environment, and its parameters must be redefined before the IAD (8)-U( ) ETU can work in your environment.

1.Boot up a PC with IP Address: 192.168.1.X, Subnet Mask: 255.255.255.0. Connect to the IAD(8)-U( ) either via a crossover cable or a small hub.

2.Connect to the IAD (8)-U( ) ETU via your Web Browser to the following link:

http://192.168.1.100/

The IAD (8)-U( ) ETU supports Microsoft Internet Explorer 5.0 and higher.

3.When the login screen appears, enter the Login ID and password. Click login.

 

Default login ID = admin

 

 

 

Default password = password

 

 

4.

Set the IP Address, Subnet Mask, Host Name, and Default IP

 

 

 

parameters in the IAD (8)-U( ) ETU Card tab and select Submit.

 

 

5.

Set the IP Station Encoding Preference, Packet Size, Jitter Depth and

 

 

 

the IP Address (or use DHCP if using a DHCP Server) under the Port

 

 

 

Tab and select Submit.

 

 

6.

Select the System tab, then select Reset the Card. The ETU goes

 

 

 

through a reboot cycle. This may take a few minutes.

 

 

7.

Disconnect the crossover cable and connect the IAD (8)-U( ) ETU

 

 

 

(MEGACO Station) to your network.

 

 

 

The ETU is now ready for operation.