June 2004 | NEC Business Solutions Ltd |
|
|
1.1Boot Up Sequence
The LED chart shows the status of the IAD(8)-U( ) ETU card during boot up. The LED conditions change as the IAD(8)-U( ) ETU passes through different boot states.
Table 1 Boot Up Sequence LED Patterns
STATE |
| D8 | D6 | D4 | D2 | D7 | D5 | D3 | D1 | D12 |
| CH1 | CH2 | CH3 | CH4 | CH5 | CH6 | CH7 | CH8 | LIVE | |
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 |
| | | | | | | | | @ |
|
|
|
|
|
|
|
|
|
|
|
2 |
| z | z | z | z | | | | | @ |
|
|
|
|
|
|
|
|
|
|
|
3 |
| | | | | | | | | @ |
|
|
|
|
|
|
|
|
|
|
|
4 |
| | | | | z | z | | | @ |
|
|
|
|
|
|
|
|
|
|
|
5 |
| | | | | | | z | z | @ |
|
|
|
|
|
|
|
|
|
|
|
6 |
| | | | | | | | | @ |
|
|
|
|
|
|
|
|
|
|
|
z= LED ON = LED OFF
@ = LED Flashing
1.2Connectors
J6 = Default Ethernet connection
1.3S2 DIP Switch Settings
Table
| Reserved |
| Auto | No. of |
|
| Mode Operation | |||
|
| Sense | Ports |
|
| |||||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
SW1 |
| SW2 | SW3 | SW4 | SW5 | SW6 | SW7 |
| SW8 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
OFF |
| OFF | OFF | ON | ON | ON | OFF |
| OFF | |
|
|
|
|
|
|
|
|
|
|
|
1.Configure DIPSW S2 in accordance to Table 2. Place the IAD(8)-U( ) ETU in the Xen IPK KSU.
2.Connect the Ethernet cable to connector J6.
3.The CH1~CH8 LEDs start to run indicating that the system is initial ising the IP Networking parameters. The Status LED (D12) is red (refer to Table 1 Boot Up Sequence LED Patterns).
4.Once all the LEDs are OFF and the Status LED (D12) is flashing red, the IAD(8)-U( ) can be set up with the system.
No. 8684 - Release 1.0 | 2004 |
Doc. | June |
34 | Hardware Setup |