Fiber Single-mode connector types:

Magnum 6K16V Managed Fiber Switch

Installation and User Guide (06/04)

Fiber Single-mode connector types:

Fiber Port, SC-type: Fiber optic single-mode, 100BASE-FX

Fiber Port, LC-type Fiber SFF single-mode, 100BASE-FX

Fiber Port, 1000BASE-FX, GBIC modules

LEDs: Per Port (one set at the port, one set in top or front) LK: Steady ON when media link is operational ACT: ON with receiver port activity

FDX/HDX: ON = Full-Duplex Mode OFF = Half-Duplex Mode

100/10: ON = 100Mbps speed OFF = 10 Mbps

Operating Environment

Ambient Temperature:

-40° to 140° F (-40° to 60°C) for UL60950 and Component Parts rating -60° to 205° F (-50° to 95°C) for IEC 60068 Type Test short term rating

Storage Temperature: -60°to 210°F (-50°to 100°C)

Ambient Relative Humidity: 5% to 95% (non-condensing)

Altitude: -200 to 13,000 ft. (-60 to 4000m)

Conformal Coating (humidity protection) option: Request quote

Alarm Relay Contacts

One NC indicating internal power, one NC software controllable

Packaging

Enclosure: Rugged High strength sheet metal. Suitable for vertical wall or DIN-Rail mounting

Dimensions: 9.5 in. H x 8.75 in. W x 1.75 in. D 24.1 cm H x 22.2 cm W x 4.4 cm D

Cooling method: Convection, designed for vertical mounting, no fans

Weight: 4.21 lbs. (1.9 kg)

Management Console connector

DB-9 for RS-232null-modem “ cable (sometimes called an X-modem cable)

Power Supply (Internal)

AC Power Connector: IEC-type, male recessed at rear of chassis,

Input Voltage: 100 to 240 VAC (auto-ranging)

Input Frequency: 47 to 63 Hz (auto-ranging) Power Consumption:

50 watts typical (for a fully loaded fiber model)

30 watts typical (for a fully-loaded copper only model)

DC Power Supply (Options)

-48VDC Power Input Voltage : -36 to -70 VDC

24VDC Power Input Voltage : 20 to 36VDC

125VDC Power Input Voltage : 115 to 150VDC

5VDC Power Input Voltage : (+) or (-) 5%

Std. Terminal Block : “ -, GND, + ”

Power Consumption: same as for AC models, see above