B1.0 SPECIFICATIONS FOR MAGNUM 6K16V SWITCHES, DC POWER

Magnum 6K16V Managed Fiber Switch

Installation and User Guide (06/04)

APPENDIX B : Internal DC Power Supply Options

B1.0 SPECIFICATIONS FOR MAGNUM 6K16V SWITCHES, DC POWER

Power Magnum 6K16V models, for –48V and 24V DC & 125VDC and 5V Power input

Each Magnum Model 6K16V Managed Switch (DC option) requires a DC power source, from for 24VDC, -48VDC and 125VDC option or 5VDC input. The wide range of power input qualifies this product for use in 24VDC, -48VDC as well as 125VDC or 5VDC environments. The 24VDC, -48VDC or 125VDC or 5VDC power input provides an Ethernet networking product utilizing a special type of power supply with a proven high-reliability record to fulfill the DC requirement.

DC Power Terminals: “+”, -,internally floating

GND: Terminal for “earth” or ground wire connection to the 6K16V chassis

Input Voltage: 18 to 36 VDC (24VDC)

Input current: 1.2Amps max.(for all RJ-45 ports)

Input current: 2.4Amps max.(for all Fiber ports)

Input Voltage: -36 to -70 VDC (-48VDC)

Input current: 0.8Amps max.(for all RJ-45 ports)

Input current: 1.2Amps max.(for all Fiber ports)

Input Voltage: 115 to 150 VDC (125VDC)

Input current: 0.3Amps max.(for all RJ-45 ports)

Input current: 0.35Amps max.(for all Fiber ports)

Power Consumption: 50 watts max., for fully loaded (fiber ports)

(24V, -48V, 125V)DC 30 watts typical for all (RJ-45 Ports)

Input Voltage: 5VDC (+) or (-) 5% (5VDC)

Input current: 3.5Amps max.(for all RJ-45 ports)

Input current: 8.0Amps max.(for all Fiber ports)

Power Consumption: 20 watts max., for fully loaded (fiber ports) 17 watts typical for all (RJ-45 Ports)

B2.0 -48VDC, 24VDC and 125VDC POWER, THEORY OF OPERATION

The -48VDC, 24VDC and

125VDC power options are designed

 

 

POWER SWITCH

 

HUB

 

 

 

 

 

 

 

 

using diodes inside on each DC power

 

 

 

 

 

 

 

SUPPLY

 

A+

 

 

 

 

 

 

+- FUSE

 

 

 

 

 

 

 

 

input line behind the two external power

A-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

connection terminals, so that the power

 

 

 

 

 

 

 

 

 

 

GND

 

 

 

 

 

 

CHASSIS

from an external source can only flow

 

 

 

 

 

 

GND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

into the hub. This allows the Switch to operate only whenever DC power is correctly

www . GarrettCom . com

51

Page 58
Image 58
GarrettCom manual B1.0 SPECIFICATIONS FOR MAGNUM 6K16V SWITCHES, DC POWER, APPENDIX B Internal DC Power Supply Options