Download 63 pages 56.28 Kb
Page 40
Image 40
4.2Status LEDs

Magnum 6K16V Managed Fiber Switch

Installation and User Guide (06/04)

4.2Status LEDs

For all Magnum 6K16V models :

PWR

: Power LED, ON when external power is applied to the unit.

LK

: Steady ON, Link status for 10 Mbps and 100Mbps operation.

ACT

: ON with port activity for 10 Mbps and 100Mbps operation.

F/H

: Full / Half duplex LED, ON when the port is running full

 

duplex, OFF for half duplex.

100/10

: Speed LED, ON when the speed is 100Mbps , OFF when the

 

speed is 10 Mbps

4.3Up-link Manual Switches set as (=) , for RJ-45 port only

The module has a manual Up-link switch, located on the inside of the board

next to the 10/100Mb (6K8-RJ45) port # 1 which it controls. It enables the port’s cable to be cascaded (X) to a 10/100Mb repeater or switching hub in the network. The Up-link Switch position is configured as (=) position by default from the factory settings on all the RJ-45 ports, either used for all copper module or combo module.

4.4Auto-negotiation, for Fast Ethernet copper ports

The Managed Magnum 6K16V Fast Ethernet copper ports can be set for either fixed 100Mb speed or for 10/100 F/H N-way auto-negotiation per the IEEE802.3u standard. The selection is made via MNS software. The factory default setting is for auto-negotiation. At 10Mb or 100Mb-fixed speed, the user may select half- or full- duplex mode by MNS Software for each RJ-45 port separately. For detail information see Section 8 (Optimizing Port usage) of Magnum 6K16V Software user guide (MNS) .

See Section (2.2.9 at page no.13) of this manual to access the “6K16V Software userguide”

One frequently-used application for the Managed Magnum 6K16V Switch copper ports is to connect one of them using a fiber media converter to another Switch in the network backbone, or to some other remote 100Mb device. In this case, it is desirable to operate the fiber link at 100Mb speed, and at either half- or full duplex mode depending on the capabilities of the remote device. Standard commercially available Fast Ethernet media converters mostly do not support auto-negotiation properly, and require that the switched port to which they are connected be at 100Mb fixed speed. Attachment to 10/100 auto-negotiation ports typically will not work properly. The 6K16V Switch’s RJ-45 ports handle this situation by configuring the ports as per desire through MNS software port settings and can check the port status of each port after the change.