NEC VT46 user manual Maintenance, Replacing the Lamp, To replace the lamp

Page 25

MAINTENANCE

This section describes the simple maintenance procedures you should follow to replace the lamp and clean the filter.

Replacing the Lamp

After your lamp has been operating for 3000 hours or longer, the LAMP indicator in the cabinet will blink red and the message will appear. Even though the lamp may still be working, replace it at 3000 hours to main- tain optimal projector performance.

CAUTION

DO NOT TOUCH THE LAMP immediately after it has been used. It will be extremely hot. Turn the projector off, wait 60 seconds, turn off the main power switch and then disconnect the power cable. Allow at least one hour for the lamp to cool before han- dling.

DO NOT REMOVE ANY SCREWS except the lamp cover screw and two lamp case screws. You could receive an electric shock.

The projector will turn off and go into stand by mode after 3100 hours of service. If this happens, be sure to replace the lamp. If you continue to use the lamp after 3000 hours of use, the lamp bulb may shatter, and pieces of glass may be scattered in the lamp case. Do not touch them as the pieces of glass may cause injury. If this happens, contact your NEC dealer for lamp replace- ment.

To replace the lamp:

1.Loosen the lamp cover screw until the screwdriver goes into a free- wheeling condition and remove the lamp cover. The lamp cover screw is not removable.

Catch

2.Loosen the two screws securing the lamp housing until the screw- driver goes into a freewheeling condition. The two screws are not removable.

Remove the lamp housing by holding it.

NOTE: There is an interlock on this case to prevent the risk of electrical shock. Do not attempt to circumvent this interlock.

Catch

Interlock

3.Insert a new lamp housing until the lamp housing is plugged into the socket.

CAUTION

Do not use a lamp other than the NEC replacement lamp (VT60LP). Order this from your NEC dealer.

Secure it in place with the two screws.

Be sure to tighten the screws.

4.Reattach the lamp cover.

Tighten the lamp cover screw. Be sure to tighten the screw.

5.After you install a new lamp, select the menu [Default] [Clear Lamp Hour Meter] to reset the lamp usage hours.

NOTE: When the lamp exceeds 3100 hours of service, the projector cannot turn on and the menu is not displayed. If this happens, press and hold the ON/STAND BY and CANCEL buttons on the remote control simultaneously for a minimum of 10 seconds while in standby mode. When the lamp time clock is reset to zero, the LAMP indicator goes out.

E-25

Image 25
Contents VT46 Safety Cautions Lamp Replacement Fire and Shock PrecautionsWhats in the Box? Table of Contents Introduction Features youll enjoyIntroduction to the Projector Congratulations on Your Purchase of The VT46 ProjectorPart Names of the Projector Top Features Terminal Panel Features Part Names of the Remote Control Remote Control Precautions Battery InstallationOperating Range for Wireless Remote Control Setting Up the Screen and the Projector Installation and ConnectionsSelecting a Location Do not attempt to install the projector yourself Distance ChartThrow Distance and Screen Size Reflecting the ImageMaking Connections Connecting Your PC or Macintosh ComputerTo connect Scart output RGB RGB Connecting Your DVD PlayerConnecting the Supplied Power Cable Connecting Your VCR or Laser Disc PlayerTurning on the Projector Projecting AN Image Basic OperationSelecting a Source Selecting the computer or video sourceAdjust the Tilt Foot Adjusting the Picture Size and PositionCorrecting the Vertical Keystone Distortion FocusAdjusting the Image Using Auto Adjust Turning Up or Down VolumeTurning off the Projector To turn off the projectorUsing the Menus Using ON-SCREEN MenuBasic Menu Operation List of Menu Items Menu Elements Picture Menu Descriptions & FunctionsImage Advanced SetupEnabling High Speed Fan Mode High Speed Fan Mode To disable the Security functionSelecting Signal Format Signal Select Page2 Enabling Power Management Power ManagementInformation DefaultReplacing the Lamp MaintenanceTo replace the lamp Cleaning or Replacing the Filter CleaningCleaning the Cabinet and the Lens To replace the filter spongePower Indicator TroubleshootingStatus Indicator Lamp IndicatorDoes not turn on Common Problems & Solutions Check These ItemsModel Number VT46 Optical SpecificationsPin Assignments of D-Sub RGB Input Connector Cabinet DimensionsMini D-Sub 15 Pin Connector Pin No RGB Signal Analog YCbCr SignalSXGA+ Compatible Input Signal ListCable Connection Communication Protocol PC Control CodesServices offered with TravelCare TravelCare a service for international travelersTerm of warranty TravelCare GuideAsia and Middle East Service are offeredApplication Sheet for TravelCare Service Program Condition of your TravelCare Service Program