Safety Notices

!WARNING

To avoid a risk of injuries, installation should be performed by trained technical personnel.

It takes at least two people to unpack your server and two people to maneuver the server, after unpacking.

Your server is equipped with a front stabilizer. Engage the front stabilizer during installation. For stability and to distribute the weight, also attach side stabilizers. Otherwise, the rack may topple over and cause injuries.

If you extend two or more devices from the rack at the same time, the rack may topple over on you. Extend only one device from the rack at a time.

Exercise great care not to hurt your fingers on the rail when you mount/dismount the equipment into/from the rack.

!Elevated Operating Ambient Temperature – If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than the room ambient environment. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum rated ambient temperature of 95°F (35°C).

!Reduced Air Flow – Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.

!To prevent fires and damage to rack equipment and supply wiring, make sure that the rated load of the power branch circuit is not exceeded. Equipment nameplate ratings should be used when addressing this concern. For more information on installation and wiring of power- related facilities, contact your electrician or local power company.

!To prevent electrical shock, connect all rack and rack support equipment to the same electrical circuit of the building wiring. If you are unsure, check the building wiring to avoid remote earth conditions.

!For safe operation, only connect the equipment to a building supply that is in accordance with current wiring regulations in your country. In the USA, those wiring standards are regulated by Underwriter Laboratories (UL); in the U.K. by the Institution of Electrical Engineers, (IEE) and in Canada by the Canadian Standards Association (CSA).

2 Express5800/1160Xd/1320Xd Installation Procedures

Image 6
Contents EXPRESS5800/1160Xd/1320Xd Proprietary Notice and Liability Disclaimer Contents Page Symbols and Conventions IntroductionSafety Notices Safety Notices for Users Outside of the U.S.A. and Canada If you Need HelpSelecting a Site Unpacking the Server Unpacking Procedure Shipping ContainerShipping Container Plastic Straps Removing the Corner and Top Protectors Styrofoam Stoppers Lower Plastic Sheathing Rolling the Server Down the Ramp Lowering the Leveling Pads Installing the Side Stabilizer Kit Attaching the Power Cables Attaching the LAN CablesConnecting and Routing the LAN Cables 1160Xd Ether Connector Page 455-01694-000