4096-00X
Power Service Check
| FRU | Action |
|
|
|
1 | Power Supply | Disconnect N1 from the system board and check |
|
| the following voltages on the power supply cable: |
|
| • |
|
| • |
|
| If you do not have correct voltage, replace the |
|
| power supply. Be sure to unplug the machine |
|
| before you reconnect the power supply to the |
|
| system board. |
|
|
|
2 | Printhead Cable | Turn off the printer. Disconnect one of the |
| Carrier Home | printhead cables and turn on the printer. Look for a |
| Sensor | symptom change. Check the failing part for shorts |
| Parallel Cable | and replace as necessary. |
|
| Repeat this procedure for the carrier home sensor |
|
| and parallel cable. |
|
|
|
3 | System Board | If the symptom has not changed, replace the |
|
| system board. |
|
|
|
Diagnostic Information