6.Verify that the rotary switch and the circuit board switch are in the OFF position.

7.Replace the case top, ensuring that the gasket is properly seated and case snaps together above the LCD (item A).

8.Reinstall the three screws and the battery door. Secure the door by turning the screws one-quarter turn clockwise.

Service and Parts

If the meter fails, check the battery and fuses. Review this manual to verify proper use of the meter.

Replacement parts and accessories are shown in Tables 9 and 10 and Figure 11.

To contact Fluke, call one of the following telephone numbers:

USA: 1-888-99-FLUKE (1-888-993-5853)

Canada: 1-800-36-FLUKE (1-800-363-5853)

Europe: +31 402-678-200

Japan: +81-3-3434-0181

Singapore: +65-738-5655

Anywhere in the world: +1-425-356-5500

Or, visit Fluke’s Web site at www.fluke.com.

36

Image 44
Contents Series Lifetime Limited Warranty Table of Contents Series List of Tables Series List of Figures Series Introduction International Electrical Symbols SeriesSafety Information Inputs Description Your Meter’s FeaturesTerminal Switch Position Rotary Switch Positions FunctionButton Function Pushbuttons Button FunctionButton Display Features Model 87 Shown 100 ms Number FeatureDisplay Features Indication Display Features Number ΜA, mA ΜF, nF Me, ke Hz, kHz, MHzPower-Up Options Automatic Power-OffMeasuring AC and DC Voltage Input Alert FeatureMaking Measurements Switch Box Testing for Continuity For in-circuit tests, turn circuit power off Measuring Resistance Disconnect Isolating a ResistorUsing Conductance for High Resistance or Leakage Tests Measuring CapacitanceMeasuring Capacitance Series Testing Diodes Testing a DiodeWWarning Measuring AC or DC CurrentCurrent through one component Series Measuring Frequency All ranges Measuring Duty Cycle Components of Duty Cycle MeasurementsModel 87 Bar Graph Analog Bar GraphDetermining Pulse Width 2 Digit Mode Model Models 83 and 85 Bar GraphMIN MAX Recording Mode MIN MAX Functions Zoom Mode Models 83 Touch Hold ModeRelative Mode General Maintenance MaintenanceUses for the Zoom Mode Models 83 Testing the Fuses 00.5 Ω Replace fuse OLTouch top half Input contactsReplacing the Battery Replacing the FusesService and Parts Battery and Fuse Replacement Quantity Replacement PartsFluke Part Or Model Number Replaceable Parts Accessories Fluke Part NumberSpecifications Models 85 and 87 AC Voltage Function Specifications KHz 20 kHz2Model 83 AC Voltage Function Specifications Model Current Function Specifications Resolution Model Model 853 Burden Voltage TypicalΜA B Capacitance and Diode Function Specifications Frequency Counter SpecificationsFrequency Counter Sensitivity and Trigger Levels AccuracyElectrical Characteristics of the Terminals MIN MAX Recording Specifications

80 Series III specifications

The Fluke 80 Series III digital multimeters are renowned for their robust engineering, precision, and versatility, making them a staple in the toolkit of electricians, engineers, and technicians. Launched by Fluke Corporation, a leading manufacturer of electronic test tools, the 80 Series III has set a benchmark in the multimeter industry for its reliability and performance.

One of the standout features of the Fluke 80 Series III is its wide measurement capabilities. The device can accurately measure AC and DC voltage, DC current, resistance, frequency, and capacitance. This comprehensive feature set allows users to tackle a variety of tasks, from simple household electrical checks to complex industrial applications. The meter's high input impedance prevents loading effects on circuits, ensuring accurate readings, especially in sensitive electronic applications.

Fluke's proprietary True-RMS technology is another defining characteristic of the 80 Series III. This technology ensures that the multimeter provides accurate readings for both non-linear loads and distorted waveforms, which are common in many modern electrical systems. This capability is particularly valuable in diagnosing issues in variable frequency drives, inverters, and other electronic systems that do not present traditional sinusoidal waveforms.

Durability is a key factor in the design of the Fluke 80 Series III. The multimeter is housed in a rugged, impact-resistant case that can withstand the rigors of fieldwork. It features a built-in protective holster with a probe holder, enhancing portability while safeguarding the device against drops and bumps. Furthermore, the 80 Series III boasts an IP67 rating for dust and water resistance, ensuring reliable performance in adverse conditions.

User-friendliness is also a significant aspect of the Fluke 80 Series III. The large, easy-to-read display, combined with intuitive controls, allows users to navigate its functions with ease. The multimeter features a backlight, enabling use in dimly lit environments, while the hold function ensures that readings can be captured and displayed even after disconnecting the probes.

In addition to these features, the Fluke 80 Series III offers various models to cater to specific needs, such as the 87V for highly accurate measurements in industrial environments and the 86V for temperature measurements with added thermocouple support. Each model maintains the high standards of quality and performance that Fluke is known for.

In summary, the Fluke 80 Series III digital multimeters combine advanced features, high accuracy, and rugged durability, making them indispensable tools for professionals who require reliable performance in challenging environments. Whether for routine maintenance or complex troubleshooting, the 80 Series III offers everything necessary to meet the demands of today’s electrical tasks.