3.2Indicators

The operation and display panel has seven indicators (see Figure 18). The indicators can be divided into two groups according to the applications: level indicators and UPS status indicators.

3.2.1Level Indicators Battery Level Indicators

The battery level indicator is composed of five sets of LED bars that illuminate and flash to indicate the battery capacity level. The Liebert® GXT3battery capacity level is shown in 20% increments (±5%). The battery level indicators will illuminate as shown in Figure 19.

Figure 19 Battery level indicators

ChargingDischarging

0 - 20%

 

 

 

 

 

 

 

 

 

 

 

 

Flash

OFF

OFF

OFF

OFF

21 - 40%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

Flash

OFF

OFF

OFF

41 - 60%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

ON

Flash

OFF

OFF

61 - 80%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

ON

ON

Flash

OFF

81 - 100%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

ON

ON

ON

Flash

Fully

 

 

 

 

 

 

 

 

 

 

Charged

 

 

 

 

 

 

ON

ON

ON

ON

ON

ON OFF OFF OFF OFF

ON ON OFF OFF OFF

ON ON ON OFF OFF

ON ON ON ON OFF

ON ON ON ON ON

ON ON ON ON ON

Load Level Indicators

The load level indicator is composed of five LED bars that illuminate to indicate the relative load on the UPS output in 25% increments (± 5%). The load level indicator will illuminate as shown in Figure 20.

Figure 20 Load level indicators

0 - 25%

26 - 50%

ON OFF OFF OFF OFF

ON ON OFF OFF OFF

51 - 75%

ON ON ON OFF OFF

76 - 100%

Overload

ON ON ON ON OFF

ON ON ON ON ON

20

Image 26
Contents Liebert GXT3 UPS 120V/208V 500VA-3000VA Page Table of Contents Operation MaintenanceTroubleshooting CommunicationFigures Page Important Safety Precautions UPS Safety NotesBattery Safety Information for the Protection of the EnvironmentGlossary of Symbols Model Nominal Power Rating FeaturesUPS models, power ratings Available ModelsFront Panel and Controls Rear Panel FeaturesAppearance and Components Ventilation Slots Operation Display PanelOutput 15RLiebert GXT3 208V rack/tower models-rear panel components Inverter Rectifier/Power Factor Correction PFC CircuitMajor Components Operating Mode Frequency Converter Mode Battery ModeBattery Recharge Mode Unpacking and Inspection Preparation for InstallationInstallation What’s IncludedConnectors Spacers Support Bases Mechanical InstallationTower Installation Front Plastic Bezel CoverLiebert UPS External Operation and Display Panel Rotated Clockwise 90 DegreesLiebert GXT3 CabinetRack Installation Pulling inner member from each slide rail assemblyInstalling front member of each slide rail assembly Installing rack-mount handles Input circuit breaker specification Connecting Input Plug and LoadsConnecting Battery Cables Cable ConnectionConnecting Communication Cables Connecting USB Communication CablesControl Buttons Controls and Indicators1 On/Alarm Silence/Manual Battery Test Button Standby/Manual Bypass ButtonLoad Level Indicators IndicatorsLevel Indicators Battery Level Indicators UPS Status Indicator Icon Color Description UPS Status IndicatorsUPS status indicators Starting the UPS Startup Checklist for the Liebert GXT3Manual Battery Test Manual BypassDisconnecting Input Power from the Liebert GXT3 Shut Down the Liebert GXT3Liebert MultiLink Liebert IntelliSlot Communication CardsCommunication USB Port Communication Configuration ProgramFactory UPS Model Default, VAC Output Voltage Option, VAC Output voltage optionTerminal Block Communication Any-Mode ShutdownLow Battery Battery Mode ShutdownOn Battery Battery Replacement Procedures Replacing the Internal Battery PackMaintenance Replacement internal battery pack model numberInternal Battery Pack Handle Pull Out with Battery Handle Battery Door Screws Front BezelBattery Connector Checking UPS Status Battery ChargingPrecautions Checking UPS FunctionsIndicators UPS SymptomsTroubleshooting Indicator Diagnosis/Audible alarmTroubleshooting Audible AlarmAudible alarm description Condition AlarmTroubleshooting Battery Cabinet Input Breaker Battery ConnectorsSpecifications Environmental Dimensions, D × W × H, in. mmWeight, lb. kg Battery cabinet specifications Operating temperature parametersBattery run times VAC RTProduct Warranty Registration Specifications Page Twor k Ne tIs t Care
Related manuals
Manual 48 pages 41.03 Kb Manual 80 pages 38.9 Kb

GXT3, 208V specifications

The Emerson 10-30 kVA, 208V uninterruptible power supply (UPS) solution is a robust system designed to provide reliable power protection for critical applications in commercial and industrial settings. This UPS is ideal for safeguarding IT equipment, communication systems, and other sensitive electronics against power disturbances and interruptions.

One of the standout features of the Emerson 10-30 kVA UPS is its modular design, allowing for flexibility and scalability. This means that as the power needs of a facility grow, the UPS can be easily expanded without requiring a complete system overhaul. This modularity contributes to a more efficient use of resources and minimizes operational costs.

The UPS also incorporates advanced technologies such as double-conversion online architecture, which provides the highest level of power quality. This technology ensures that the output power is consistently clean and stable, effectively eliminating harmful voltage fluctuations and frequency variations. Consequently, connected load receives a pure sine wave output, preventing potential damage or operational issues with sensitive equipment.

Another key feature is the high efficiency rating of the Emerson UPS, which exceeds 95 percent in typical operating conditions. This high efficiency translates to reduced energy costs and a smaller carbon footprint, aligning with modern sustainability goals. The cooling system is designed to be efficient as well, ensuring optimal performance while maintaining a compact footprint.

The user-friendly interface enhances operability, featuring an intuitive LCD display that allows for easy monitoring of critical power parameters. Users can access real-time data related to battery health, load levels, and operational status, which aids in effective management of the power supply.

Battery management is another critical aspect of the Emerson UPS. It employs advanced battery management technologies to ensure optimal battery life and performance. Features such as intelligent battery testing and monitoring help predict potential battery failures before they occur, allowing for proactive maintenance and minimized downtime.

In summary, the Emerson 10-30 kVA, 208V UPS offers a combination of modularity, high efficiency, advanced technologies, and effective power management features that cater to the demanding needs of critical applications. With its reliable performance and user-friendly operation, this UPS solution is an excellent choice for organizations looking to protect their valuable equipment from power disturbances.