Philips 150X user manual FAQs Frequently Asked Questions

Page 40

FAQs (Frequently Asked Questions)

Q:How does a TFT LCD Panel work?

A:On each column and row of the TFT LCD panel, a data source drive and a gate drive and attached

respectively. The TFT drain of each cell is connected to the electrode. The molecular arrangement of liquid crystal elements differs depending on whether it is impressed with voltage or not. It varies the direction of polarized light and the amount of light by letting it through different arrays of liquid crystal elements. When two polarized filters are arranged vertically on a polarized light pole, the light that passes through the upper polarized panel is turned 90 degrees along with spiral structure of the liquid crystal molecules, and goes through the polarized filter at the bottom. When impressed with voltage, liquid crystal molecules are arranged vertically from the original spiral structure and the direction of the light is not turned in 90 degrees. In this case, light that comes through the top polarized panel may not go through the polarized panel at the bottom.

Q:What are the advantages of TFT LCD compared to CRT?

A:In a CRT monitor, a gun shoots electrons and general light by colliding polarized electrons on

fluorescent glass. Therefore, CRT monitors basically operate with analog RGB signal. A TFT LCD monitor is a device displaying an input image by operating liquid crystal panel. The TFT has a fundamentally different structure than a CRT: Each cell has an active matrix structure and independent active elements. A TFT LCD has two glass panels and the space between them is filled in with liquid crystal. When each cell is connected with electrodes and impressed with voltage, molecular structure of liquid crystal is altered and controls amount of inlet lighting to display images. A TFT LCD has several advantages over a CRT, since it can be very thin and it does not have flickering because it does not use scanning method.

Q:Vertical frequency of 60Hz optimal for an LCD monitor, why?

A:Unlike a CDT monitor, the TFT LCD panel has a fixed resolution. For example, an XGA monitor

has 1024x3 (R, G, B) x 768 pixels and higher resolution may not be available without additional software processing. The panel is designed to optimize display for 65MHz dot clock, one of the standards for XGA displays. Since the vertical/horizontal frequency for this dot clock is 60/48Hz, the optimum frequency for this monitor is 60Hz.

Q:What kind of wide-angle technology is available? How does it work?

A:The TFT LCD panel is an element controls/displays inlet of a backlight using the dual-refraction

of liquid crystal. Using the property that the projection of inlet light refracts toward the major axis of the liquid element, it controls the direction of inlet light and displays it. Since the refraction ratio of inlet light on liquid crystal varies with the inlet angle of the light, the viewing angle of a TFT is much narrow than that of a CDT. Usually, viewing angle refers to the point where the contrast ration is 10. Many ways to widen the viewing angle are currently being developed the most commonly used approach is to use a wide viewing angle film, which widens viewing angle by varying the refraction ratio. Also IPS (In Plane Switching) or MVA (Multi Vertical Aligned) is used for wider viewing angle.

file:///D/Philips LCD/english/150X/SAFETY/SAF_FAQ.HTM (7 of 9) [4/18/2001 9:12:53 AM]

Image 40
Contents Page Safety precautions and maintenance Safety and Troubleshooting InformationInstallation Locations Correct handling of the monitor Return to TOP Other Documents You May Need About This GuideNotational Descriptions Return to TOP Technical Specifications Product FeaturesProduct Information Audio Resolution & Preset Modes Automatic Power SavingPhysical Specifications Signal Pin AssignmentDVI-I Pin Assignment Views No Video Input Entering Sleep Mode Page Installing your LCD Monitor Rear View Side View Return to TOP Optimizing Performance On-Screen Display Description of the On Screen DisplayAnalog signal input OSD TreePage Digital signal input Return to TOP Customer Care & Warranty North America Canada USAGlossary BNC connectionSUB USB LCD Liquid Crystal Display Vertical refresh rate Return to TOP Download and Print Download instructionsInstalling FPadjust Program Printing instructionsFAQs Frequently Asked Questions General FAQsFAQs Frequently Asked Questions Page Screen Adjustments Compatibility with other Peripherals LCD Panel Technology FAQs Frequently Asked Questions Ergonomics, Ecology, and Safety Standards Return to TOP Troubleshooting Common ProblemsImaging Problems Return to TOP Regulatory Information TCO Development Unit Philips Federal Communications Commission FCC Notice U.S. Only EN 55022 Compliance Czech Republic Only Varning Earthed How to connect a plug Information for Users in the U. S Other Related InformationInformation for Users outside the U.S Philips Pixel Defect Policy Philips Flat Panel Monitors Pixel Defect PolicyProximity of Pixel Defects Return to TOP Connecting to Your PC Connecting to Your PC Connecting to Your PC Connecting to Your PC Return to TOP Getting Started Getting StartedOSD Controls BrightnessLanguage Adjust Position Brightness & Contrast Brightness & Contrast Video Noise not available on all monitors OSD Controls Adjust COLORanalog mode OSD Controls OSD Controls OSD Settings OSD Controls Product Information Reset to Factory Settings Monitor, Reset to Factory Settings is your last selection Input Selection not available on all monitors Close Main Controls Page Your International Philips F1rst Choice Warranty Thank you for purchasing this Philips monitorYour International Guarantee Limited Warranty Computer Monitor WHO is COVERED? What is COVERED?Before Requesting Service Philips Customer Care Center, P. O. Box 2976, Longview, TX