Philips BDL3215E, BDL4225E user manual Remote control numbering function, Video VGA BNC

Page 43

User Manual BDL3215E / BDL4225E

NOTE 3: “PIP”, “POP” and “SIDE BY SIDE”

The following table shows the combination of signal inputs under “PIP” and “POP” modes are activated. These modes do not function when the screen size is “CUSTOM” or “REAL”.

 

 

 

 

 

 

SUB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HDMI

 

DVI-D

VGA

COMPONENT

S-VIDEO

VIDEO

VGA(BNC)

 

 

 

 

 

 

 

 

 

 

 

HDMI

°

 

°

{

{

{

{

{

 

 

 

 

 

 

 

 

 

 

 

DVI-D

°

 

°

{

{

{

{

{

 

 

 

 

 

 

 

 

 

 

 

VGA

{

 

{

°

{

{

{

{

MAIN

 

 

 

 

 

 

 

 

 

COMPONENT

{

 

{

{

°

{

{

°

 

 

 

 

 

 

 

 

 

 

 

S-VIDEO

{

 

{

{

{

°

°

{

 

 

 

 

 

 

 

 

 

 

 

VIDEO

{

 

{

{

{

°

°

{

 

 

 

 

 

 

 

 

 

 

 

VGA (BNC)

{

 

{

°

°

{

{

°

 

 

 

 

 

 

 

 

 

 

 

 

{: Supported

 

°: Not supported

 

 

 

Press the “PIP ON/OFF” buttons on the remote control to change between “PIP”, “POP” and “SIDE BY SIDE” mode as shown in the diagram below.

PIP

POP

SIDE BY SIDE

SIDE BY SIDE

OFF

ASPECT

FULL

 

 

 

 

A

B

A

B A B A B A

“PIP”, “POP” mode resolution (Reference)

 

 

 

 

PIP SIZE

Y

SMALL

Z : 320 dots X 240 dots

 

Y

MIDDLE

Z

: 480 dots X 320 dots

 

Y

LARGE

Z

: 640 dots X 480 dots

POP SIZE

 

 

 

: 320 dots X 240 dots

< Remote control numbering function >

By connecting multiple BDL3215E/BDL4225E monitors by using RS-232C cables, you can control any or all monitors by one remote control.

1.Assign arbitrary ID number to each of multi-connected BDL3215E/BDL4225E monitors by using MONITOR ID. ID numbers 1 to 26 are selectable.

,WLVUHFRPPHQGHGWRDVVLJQVHTXHQWLDO,'QXPEHUVIURPDQGXS

2.The remote control mode of the first BDL3215E/BDL4225E monitor is set to PRIMARY and the other monitors are set to

SECONDARY.

3.When you direct the remote control at the remote control signal sensor of the PRIMARY monitor and press the DISPLAY button on the remote controller, the ID selection OSD appears at the upper left of the screen.

ID: 1

ID No. : 2

ID number of the currently viewed monitor

Select the ID number of the monitor you want to control using the +/- button on the remote controller. The ID of the monitor you want to control is displayed at the upper left of its screen.

By selecting ALL, you can control all the multi-connected monitors.

4.Direct the remote control at the remote control signal sensor of the PRIMARY monitor. OSD appears on the monitor will have the ID number you selected.

NOTE:

When the ID selection OSD is being displayed on the PRIMARY monitor, press the DISPLAY button on the remote controller again to cancel the ID selection OSD and then control the monitor you selected.

HINT:

If you set the remote control mode wrongly and remote control operation becomes unavailable, press MENU button on the control panel of the monitor to display the OSD screen and change the remote control mode using ADVANCED OPTION. By pressing and holding down the DISPLAY button on the remote control for 5 seconds or longer, the remote control mode is initialized to NORMAL.

40

Image 43
Contents Public Signage Solutions Page Table of Contents Safety Instructions Regulatory Information CE Declaration of Conformity Polish Center for Testing and Certification Notice Information for UK only How to connect a plug10 For customers in Canada and U.S.A North Europe Nordic Countries InformationContents Control Panel Elements Name and Functions S-VIDEO in connector Mini DIN 4 pin To input  Video in connector BNC To input compositeTerminal Panel Remote Control Handling the remote control Operating Range for the Remote ControlHow to install table stand How to mount or attach table stand to the LCD MonitorUpright position How to remove the table stand Ventilation Requirements for enclosure locating Way II Mount the monitor on the wallSetup Procedure To prevent the main power switch from being changed How to Remove the Logo for landscape mode? Install the LCD Monitor in Portrait ModeHow to Use the Logo Guider for Portrait Mode? Connectivity Connectivity DiagramBefore making connections Connecting the LCD Monitor to a Personal Computer Connecting to a Personal ComputerConnect the LCD Monitor to a Computer with a Digital Output Connecting to a Digital Interface EquipmentConnect the LCD Monitor to a DVD Player Connecting to a DVD PlayerRQQHFWWKH/&0RQLWRUWRD6WHUHR$PSOLÀHU RQQHFWLQJWRD6WHUHR$PSOLÀHUUsing the remote control Power on and OFF ModesPressing the Main Power Switch Pressing the power buttonPicture Size Power IndicatorUsing Power Management Display Signal of Video Source Setting to VideoOSD Information Smart Picture ModeAudio Source Switching Control Lock ModeOSD screen OSD On-Screen-Display ControlsPicture Color Color TemperaturePicture Reset TintPosition Clock PhaseZoom Mode ScreenCustom Zoom Screen ResetTreble Audio ResetAudio BalancePIP Audio PIP ResetPIP Picture in Picture PIP SizeConfiguration Factory Reset Configuration ResetOSD H Position Sleep TimerOSD Turn OFF Information OSDMonitor Information BNC Video ModeAdvanced Option Schedule IR ControlTiling Date and TimeAdvanced Option Reset Smart PowerMonitor ID Image Sticking of LCD Panel Image PersistenceRecommendations Video VGA BNC Remote control numbering functionPixels and Sub-pixels Pixel defect policyDark Dot Defects Troubleshooting No Signal is displayed on the screen SCHEDULE/SLEEP Timer function is not working properlyStripe Noise Dimension Input SignalOutput Signal Power SupplyPlug & Play Power ManagementPower consumption Complied Regulatory and GuidelinesMent Operational EnvironVesa Compatible arm mounting interface Normal on 215W typical, 220W max Standby 1W, standby mode Pin Assignment 6SHFLÀFDWLRQVDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFH