BLACK BOX® Media Converter Switches | Installation and User Guide |
Fig 2.2.b LBH100A-H with
100Mb SC connector
The LBH100A-P and LBH110A-P series (as shown in Fig. 2.2c) are extreme rated units suitable for temperature un-controlled outdoor applications. Specially designed with extreme-grade extended temperature components, the LBH100P and LBH110A- P units use similar thermal techniques to the LBH100A-H hardened units for cooling. Mounting options include panel-
mounting, DIN-rail, or rack-mount tray. Choices of models for external AC or internal DC power are available. Ambient operating temperature is between –40°C to +75°C depending on the power source used. Storage temperature rating is between –40°C to +85°C.