Black Box RS-232, RS-422, RS-485, 1-Port 10/100 Device Server Appendix B Disable System Firmware

Page 49

Appendix B: Disable System Firmware

Appendix B: Disable System Firmware

The application program (AP) LES301A firmware can be disabled. Do this if you downloaded a wrong version of firmware that caused the system to crash.

To disable the current version of firmware and prevent it from executing, do the following:

1.Turn off the power, open the LES301A case.

2.Short Pin 1 and Pin 2 of Jumper JP1 on the right-top corner of the main board to disable AP firmware.

3.Power on the LES301A.

4.Download the correct AP firmware to LES301A.

5.Remove Pin 1 and Pin 2 of Jumper JP1 to enable AP firmware.

6.Close the case and continue operation.

LES301A user manual

724-746-5500 blackbox.com

Page 49

 

 

Image 49
Contents Port 10/100 Device Server, RS-232/422/485, DB9 M Trademarks Used in this Manual Trademarks Used in this ManualFCC and IC RFI Statements NOM Statement Table of Contents Diagnostics Specifications Hardware Specifications SpecificationsSoftware Specifications DB9 Pin Assignments Shows the LES301A unit’s DB9 connector pin assignmentsEthernet Port RJ-45 LAN LED Power Terminal Block ConnectorCOM Port LED LAN LEDRUN LED RUN LEDOverview Introduction OverviewWhat’s Included Hardware DescriptionDC 9-30 Button 10-/100-Mbps Port DIN rail screw hole Application ConnectivityDB9 male serial port Serial portEthernet Serial bus Card Reader LES301A CardTouchscreen Serial bus Hardware Setup Hardware SetupLED Indicators 3.1.1 LAN LED DC 9-30 Port DIN rail screw holeRUN LED message Installation Procedures LES301A-KIT or LES301AE-KITSoftware Setup Software SetupConfiguration by SerialManager Static IP Auto IP Dynamic IP Static IP setup dialog windowLog into the System Configuration by Telnet UtilitySoftware Setup Networking 4 COM1 Setup Change the PasswordSoftware Setup 11. Link Mode-TCP server setup Configure the LES301A as a TCP Client12. Link mode TCP client setup Configure the LES301A as a UDP ClientEnabling the Serial Data Buffer COM Port SettingAccept Control Command from COM Port Setting Packet DelimiterConfiguration Using Web Browser Log in to the System 19. Overview 20. Change the password21. COM type selection Network Setup22. Network setup 23. LINK1 setup-TCP server Configure the LES301A as a TCP Server24. COM1 setup-TCP server Configure the LE301A As a TCP ClientPair Connection 25. COM1 setup-TCP clientSoftware Setup 28. Configuration is successful Assign a New IP Address by ARP Command30. Assigning a new IP address by ARP command Using Virtual COM Using Virtual COMSetup of a Virtual COM Driver Pre-installation Requirements Supported FirmwareUninstalling InstallationLimitation Run Serial/IP on PC Enable Virtual COM via TelnetConfiguring Virtual COM Ports Using Virtual COM Snmp Setup Snmp Network Management Platform Snmp SetupUsing NetworkView as an Example NetworkView display device information Start Writing Your Own Applications Start Writing Your Own ApplicationsPreparing the System Running the Sample ProgramTCPTEST2 in Visual C Diagnostics DiagnosticsUse the Standard TCP/IP Utility Ping Command Use the SerialManager Configuration Utility ProgramAppendix a Upgrade System Firmware Upgrade Procedures Appendix a Upgrade System FirmwareError Messages Critical Issues of UpgradingAppendix B Disable System Firmware Appendix B Disable System FirmwareInterface Appendix C Using SerialManager UtilityFunctions Device Search Table C-1. CautionsAppendix C Using SerialManager Utility Appendix C Using SerialManager Utility Figure C-7. Download firmware FirmwareFigure C-9. Download firmware from disk Figure C-11. Network Setting screen ConfigurationSnmp Appendix C Using SerialManager Utility Appendix C Using SerialManager Utility Appendix C Using SerialManager Utility Figure C-16. Web browser Configure by Telnet Security Virtual COM Figure C-20. Change Password screenAppendix C Using SerialManager Utility Appendix C Using SerialManager Utility About Figure C-25. Virtual COM Settings screenFigure C-26. SerialManager screen Blackbox.com Black Box Tech Support FREE! Live /7
Related manuals
Manual 17 pages 33.48 Kb Manual 32 pages 55.83 Kb Manual 22 pages 44.9 Kb Manual 20 pages 11.67 Kb Manual 2 pages 48.68 Kb Manual 3 pages 1.3 Kb Manual 3 pages 62.87 Kb Manual 17 pages 29.01 Kb Manual 3 pages 56.04 Kb Manual 28 pages 51.61 Kb Manual 4 pages 387 b

RS-422, RS-485, 1-Port 10/100 Device Server, RS-232 specifications

The Black Box IC113C and IC175C are part of a series of versatile RS-485 interface converters designed to facilitate reliable data transmission over long distances. RS-485 is a standard defining the electrical characteristics of drivers and receivers for use in serial communications systems, and these specific Black Box converters exemplify the technology's adaptability and robustness.

The IC113C is an RS-485 to RS-232 converter, providing a seamless transition between these two common serial communication protocols. With a compact design, it boasts an operating temperature range of -40 to 85 degrees Celsius, making it suitable for harsh environmental conditions. Its key feature includes the ability to extend the communication distance up to 4,000 feet, which is ideal for industrial applications where devices may be far apart. Additionally, the IC113C includes built-in surge protection, ensuring that the device can withstand electrical noise and spikes, ultimately increasing the system's reliability.

On the other hand, the Black Box IC175C serves as an RS-485 to USB converter, bridging older serial devices with modern USB interfaces. This converter is critical for users wanting to connect legacy equipment to contemporary computing systems. Featuring a plug-and-play design, the IC175C is easy to install with no external power supply required, as it is powered directly through the USB connection. It also supports data rates up to 115.2 Kbps, ensuring fast and efficient data transfer.

Both models employ differential signaling, which enhances noise immunity and allows for greater transmission distances compared to single-ended communication standards. Furthermore, the converters support multiple nodes on the same bus, accommodating a network of devices without requiring complex wiring schemes.

In summary, the Black Box IC113C and IC175C offer essential features that cater to diverse industrial and commercial applications. With their robust construction, extensive operating ranges, and compatibility with various communication protocols, these converters enhance system interoperability and provide durable solutions for long-distance data communication needs. Whether connecting legacy systems or extending communication capabilities, these devices exemplify reliability and efficiency in modern data transmission technologies.