Black Box RS-485, RS-422, RS-232 user manual Appendix C Using SerialManager Utility

Page 58

Appendix C: Using SerialManager Utility

COM property represents the parameter of the serial port including: serial port type, baud rate, data bit, stop bit, parity bit, data packet delimiter, and flow control, etc.

Locate

Apply this function to locate a device when you know its IP address but you don’t know its position. If you locate the device, it will beep. Locate the device by selecting the Configuration submenu “Locate” or by clicking the “Locate” button on the toolbar.

Reset

Restart the device after you configure the parameters. You can also carry out a restart through the submenu option “Reset.”

Import Setting

If a network has a large number of devices that are used for the same purpose, it would be very complicated to configure the parameters for each device in the network one by one. You can import the parameter configuration from a parameter file directly into all the devices in the network through the submenu option “Import setting” or by clicking the “Import setting” button on the toolbar. The import parameter settings dialog box is shown below.

Figure C-14. Import a File dialog box.

You can also select several devices at once, and upload the configuration file into all the selected devices by selecting “Apply for all selected devices have same model.”

Page 58

724-746-5500 blackbox.com

LES301A user manual

 

 

Image 58
Contents Port 10/100 Device Server, RS-232/422/485, DB9 M Trademarks Used in this Manual Trademarks Used in this ManualFCC and IC RFI Statements NOM Statement Table of Contents Diagnostics Specifications Hardware Specifications SpecificationsSoftware Specifications DB9 Pin Assignments Shows the LES301A unit’s DB9 connector pin assignmentsEthernet Port RJ-45 COM Port LED Power Terminal Block ConnectorLAN LED LAN LEDRUN LED RUN LEDWhat’s Included OverviewOverview Introduction Hardware DescriptionDB9 male serial port Application ConnectivityDC 9-30 Button 10-/100-Mbps Port DIN rail screw hole Serial portEthernet Serial bus Card Reader LES301A CardTouchscreen Serial bus LED Indicators 3.1.1 LAN LED Hardware SetupHardware Setup DC 9-30 Port DIN rail screw holeInstallation Procedures LES301A-KIT or LES301AE-KIT RUN LED messageSoftware Setup Software SetupConfiguration by SerialManager Static IP Static IP setup dialog window Auto IP Dynamic IPConfiguration by Telnet Utility Log into the SystemSoftware Setup Networking Change the Password 4 COM1 SetupSoftware Setup Configure the LES301A as a TCP Client 11. Link Mode-TCP server setupConfigure the LES301A as a UDP Client 12. Link mode TCP client setupCOM Port Setting Enabling the Serial Data BufferAccept Control Command from COM Port Setting Packet DelimiterConfiguration Using Web Browser Log in to the System 20. Change the password 19. OverviewNetwork Setup 21. COM type selection22. Network setup Configure the LES301A as a TCP Server 23. LINK1 setup-TCP serverConfigure the LE301A As a TCP Client 24. COM1 setup-TCP server25. COM1 setup-TCP client Pair ConnectionSoftware Setup Assign a New IP Address by ARP Command 28. Configuration is successful30. Assigning a new IP address by ARP command Setup of a Virtual COM Driver Pre-installation Requirements Using Virtual COMUsing Virtual COM Supported FirmwareUninstalling InstallationLimitation Enable Virtual COM via Telnet Run Serial/IP on PCConfiguring Virtual COM Ports Using Virtual COM Snmp Setup Snmp Network Management Platform Snmp SetupUsing NetworkView as an Example NetworkView display device information Preparing the System Start Writing Your Own ApplicationsStart Writing Your Own Applications Running the Sample ProgramTCPTEST2 in Visual C Use the Standard TCP/IP Utility Ping Command DiagnosticsDiagnostics Use the SerialManager Configuration Utility ProgramAppendix a Upgrade System Firmware Appendix a Upgrade System Firmware Upgrade ProceduresCritical Issues of Upgrading Error MessagesAppendix B Disable System Firmware Appendix B Disable System FirmwareFunctions Device Search Appendix C Using SerialManager UtilityInterface Table C-1. CautionsAppendix C Using SerialManager Utility Appendix C Using SerialManager Utility Firmware Figure C-7. Download firmwareFigure C-9. Download firmware from disk Configuration Figure C-11. Network Setting screenSnmp Appendix C Using SerialManager Utility Appendix C Using SerialManager Utility Appendix C Using SerialManager Utility Figure C-16. Web browser Configure by Telnet Security Figure C-20. Change Password screen Virtual COMAppendix C Using SerialManager Utility Appendix C Using SerialManager Utility Figure C-25. Virtual COM Settings screen AboutFigure C-26. SerialManager screen Blackbox.com Black Box Tech Support FREE! Live /7
Related manuals
Manual 17 pages 33.48 Kb Manual 32 pages 55.83 Kb Manual 22 pages 44.9 Kb Manual 20 pages 11.67 Kb Manual 2 pages 48.68 Kb Manual 3 pages 1.3 Kb Manual 3 pages 62.87 Kb Manual 17 pages 29.01 Kb Manual 3 pages 56.04 Kb Manual 28 pages 51.61 Kb Manual 4 pages 387 b

RS-422, RS-485, 1-Port 10/100 Device Server, RS-232 specifications

The Black Box IC113C and IC175C are part of a series of versatile RS-485 interface converters designed to facilitate reliable data transmission over long distances. RS-485 is a standard defining the electrical characteristics of drivers and receivers for use in serial communications systems, and these specific Black Box converters exemplify the technology's adaptability and robustness.

The IC113C is an RS-485 to RS-232 converter, providing a seamless transition between these two common serial communication protocols. With a compact design, it boasts an operating temperature range of -40 to 85 degrees Celsius, making it suitable for harsh environmental conditions. Its key feature includes the ability to extend the communication distance up to 4,000 feet, which is ideal for industrial applications where devices may be far apart. Additionally, the IC113C includes built-in surge protection, ensuring that the device can withstand electrical noise and spikes, ultimately increasing the system's reliability.

On the other hand, the Black Box IC175C serves as an RS-485 to USB converter, bridging older serial devices with modern USB interfaces. This converter is critical for users wanting to connect legacy equipment to contemporary computing systems. Featuring a plug-and-play design, the IC175C is easy to install with no external power supply required, as it is powered directly through the USB connection. It also supports data rates up to 115.2 Kbps, ensuring fast and efficient data transfer.

Both models employ differential signaling, which enhances noise immunity and allows for greater transmission distances compared to single-ended communication standards. Furthermore, the converters support multiple nodes on the same bus, accommodating a network of devices without requiring complex wiring schemes.

In summary, the Black Box IC113C and IC175C offer essential features that cater to diverse industrial and commercial applications. With their robust construction, extensive operating ranges, and compatibility with various communication protocols, these converters enhance system interoperability and provide durable solutions for long-distance data communication needs. Whether connecting legacy systems or extending communication capabilities, these devices exemplify reliability and efficiency in modern data transmission technologies.