CHAPTER 4: Installation and Configuration

4. Installation and Configuration

This chapter describes how to install and configure your Ultra2 LVD SCSI Host Adapter. (If you are installing multiple Adapters in a clustered system, refer to Section 4.5.) If you have any difficulty, please refer to Section 6.1.

4.1 Installing the Adapter Itself

Follow these instructions to install your Ultra2 LVD SCSI Host Adapter:

NOTE

If you’re running Windows NT on the computer you’ll be installing the Adapter in, you might want to install the driver before you install hardware. If so, follow the procedure listed in Section 5.4.

1.Turn OFF your computer, unplug it, and disconnect it from all other devices.

2.Take precautions to keep from damaging the Adapter with any accidental static discharge. At the very least, discharge yourself on a metal part of the PC chassis or on some other metallic surface before touching the Adapter. If possible, stand on an anti-static mat and wear a grounding strap or anti-static gloves.

3.(Optional) If you need to hardwire termination on the Adapter so that it’s always enabled (ON), install the necessary jumper(s) on the Adapter if you haven’t done so already. See Section 3.4.

4.Remove the cover from the computer case.

5.Locate an unused 32-bit PCI expansion slot (the slot must support busmastered data transfers). PCI slots are shorter than ISA or EISA slots and are typically white. Usually there are several of them on the motherboard. (One of these might be a shared slot into which you can insert either an ISA/EISA board or a PCI board.) Refer to your PC’s documentation if you’re still not sure which ones are the PCI slots.

Once you’ve located a PCI slot, unscrew and remove the metal bracket that covers the card-slot opening. (Save the screw; you will be using it to secure the host adapter in your computer.)

21

Image 22
Contents Ultra Wide SCSI-2 LVD Host Adapter FCC/IC Statements ULTRA2 LVD Scsi Host Adapter Trademarks ULTRA2 LVD Scsi Host Adapter NOM Statement Contents Table of Contents Contents Specifications Temperature Features IntroductionULTRA2 LVD Scsi Host Adapter Adapter Illustrated Adapter’s circuit boardAdapter and the Scsi Bus Scsi ID NumbersBefore You Install Getting Started SCSI-Bus Length SCSI-Bus TerminationExamples of SCSI-bus termination ULTRA2 LVD Scsi Host Adapter Hardwiring termination Attaching Legacy Equipment Complete PackageInstallation and Configuration Installing the Adapter ItselfInserting the Adapter in a PCI slot LED connection Attaching Other Scsi Devices to the Adapter’s Bus Adapter’s included internal ribbon cablePlugging a narrow internal cable into the Adapter Connecting External Scsi Devices Initial Startup An external Scsi daisychainWHY YOU Need to do this Multiple Initiators and Clustering Setup Utility Simple multiple-initiator systemSmartSCSI Device Setup menu screen Scan BUS Screen Installation and Configuration Adapter Setup Menu Bios Setup Menu Disk Utility Menu Driver Installation Installing Drivers for MS-DOSInstalling the Aspi Driver in AN Existing MS-DOS System Aspi CD-ROM Driver and ITS COMMAND-LINE Options CONFIG.SYS Aspi REMOVABLE-DISK Driver and ITS Command Line Options ULTRA2 LVD Scsi Host Adapter Aspi Partition & Format Utility Installing Drivers for Windows NEW Windows 95/95A Installation ULTRA2 LVD Scsi Host Adapter Updating the Windows 95 Driver in Widows 95/95A NEW Windows 95B OSR2 Installation Driver Installation AULTRA2 LVD Scsi Host Adaptername NEW Windows 98 Installation ULTRA2 LVD Scsi Host Adapter Driver Installation Updating the Windows 98 Driver Installing Drivers for Windows NT Regular NEW Windows NT Installation NEW Windows NT Installation from a Bootable CD Diskless NEW Windows NT Installation Driver Installation ULTRA2 LVD Scsi Host Adapter Installing Drivers for Novell NetWare \NETWARE\HAM\INIA100.DDIPCI.XXXX.XXXX.XXXX.XXXX.XX Adding the Netware Driver to AN Existing Netware System ULTRA2 LVD Scsi Host Adapter COMMAND-LINE Options for the Device Drivers Specifies maximum decimal number of tag commands per target Installing Drivers for IBM OS/2 BASEDEV=INIA100.ADD SET COPYFROMFLOPPY=1 Adding the OS/2 Driver to AN Existing OS/2 System COMMAND-LINE Options for the Device Driver Assigns adapter number based on Bios address Installing Drivers for Linux Installing Drivers for SCO Unix Cd /etc/conf/cf.d Enter Linkunix Enter Attach Number Lun Bus Installing Drivers for SCO UnixWare Enter Etc/conf/bin/idbuild -Ma100 Enter Cd / Enter Removing the Driver from a Unixware System Troubleshooting Installation-Time ProblemsTroubleshooting ULTRA2 LVD Scsi Host Adapter Calling Black Box Shipping and PackagingPage Page Page Copyright 1999. Black Box Corporation. All rights reserved

SCSI-2 LVD specifications

The Black Box SCSI-2 LVD (Low Voltage Differential) represents a significant advancement in data storage and connectivity technology, particularly in environments requiring high performance and reliability. As a variant of the SCSI (Small Computer System Interface) standard, it is optimized for faster data communication, essential for modern computing needs.

One of the main features of SCSI-2 LVD is its capability to handle increased data transfer speeds compared to its predecessors. It supports a maximum data transfer rate of up to 80 MB/s, which is double that of the original SCSI-2 single-ended signaling. This increase in speed is largely due to the differential signaling that LVD employs, allowing for reduced electromagnetic interference and extended cable lengths while maintaining signal integrity. The technology effectively converts the SCSI bus into a more robust system that can accommodate various devices without compromising performance.

The SCSI-2 LVD standard is backward compatible, meaning that it can interface with older SCSI devices, albeit at reduced speeds. This compatibility is significant for users looking to upgrade their systems without discarding existing hardware. This makes SCSI-2 LVD an attractive choice for enterprise environments where legacy systems are common.

Another key characteristic is the flexible cabling options provided by SCSI-2 LVD. It can support cable lengths of up to 12 meters, which is beneficial for large data center configurations where space between devices can be substantial. This extended range does not typically come at the expense of performance, ensuring that data integrity remains high, even over longer distances.

In terms of technology, LVD employs lower voltage levels, which not only contributes to greater power efficiency but also minimizes heat generation in devices. This is particularly crucial in data centers where temperature management can impact hardware longevity and reliability. The combination of lower voltage use and differential signaling makes SCSI-2 LVD well-suited for high-density environments.

Error correction and handshaking features are also integral to SCSI-2 LVD, enhancing its robustness against data loss during transmission. These characteristics make it a reliable choice for applications requiring consistent and high-speed data access, such as server arrays and high-performance computing tasks.

Overall, Black Box SCSI-2 LVD stands out due to its impressive speed, compatibility, and extensive cabling options, positioning it as a reliable solution for demanding data environments. It effectively bridges the gap between legacy systems and modern technology, ensuring that users can optimize their data handling capabilities without significant disruption.