Black Box 39005, 39004 manual Figure A-1. Attenuation diagram

Page 19

T1 FIBER OPTIC LINE EXTENDER/SIMULATOR

(max, cable [2] att.)=(fiber optic power budge) - (right part att.) = 17 dB - 12 dB = 5 dB.

(max. cable [2] length) = (max.cable [2] att.)/(cable [2] att. factor) = 5 dB/3 dB/km = 5.6 km

Example 2: Maximum length of cable [2] when connected directly (without

splices, etc.): (max. cable [2] length) = (fiber optic power budget)/(cable [2] att. factor) = 17 dB/3 dB/km = 5.6 km

Example 3: Minimum cable quality to bridge 5 km (single cable without splices or

patches): (cable att. factor) = (cable att.)/(cable length) = 17 dB (fiber optic power budget)/5 km = 3.4 dB/km

1

1

T1 Fiber Optic Line

Extender/Simulator

2

4

3

5

6

T1 Fiber Optic Line Extender/Simulator

7

23

4

5

6

7

Figure A-1. Attenuation diagram.

18

Image 19
Contents T1 Fiber Optic Line Extender/Simulator FCC Information T1 Fiber Optic Line EXTENDER/SIMULATOR NOM Statement Fiber Optics General Safety PrecautionsTransport, Installation, and Operation Mains PowerTrademarks Used in this Manual TrademarksContents Specifications Typical Application FeaturesIntroduction DescriptionConnector, Indicator, or Control Connectors, Indicators, ControlsLocation of Jumpers on the Printed Circuit Board SetupSetting Description FO/S LED Clock Mode Comments SetupData Signals at Normal Mode Data SignalsData Signals Introduction Appendix Fiber Optic Planning GuidelinesExample values for calculations below See Figure A-1 Fiber Optic CalculationFigure A-1. Attenuation diagram Operation Diagram Figure A-2. Operation Diagram Figure A-3. Your Application Copyright 2000. Black Box Corporation. All rights reserved