CHAPTER 3: Installation
3.3 System Synchronization
ASYNCHRONOUS MODE
Strap the J6 jumper over the ASYNC pins. All attached equipment must be asynchronous. Turn the BIT RATE rotary switch (BRI) to the correct system speed. No other adjustments to the PSD are necessary.
SYNCHRONOUS MODE
Strap the J6 jumper over the SYNC pins (this is the
1.Synchronization on the PSD’s internal clock.
•Main channel: Equipment attached to the main channel should be set to external clock.
•
•BIT RATE rotary switch: Set BRI to the correct system speed.
2.Synchronization on the equipment attached to the main channel.
•Main channel: Equipment attached to the main channel should be set to internal clock.
•
•BIT RATE rotary switch: Set BRI to the correct system speed.
•Jumper J7: If the equipment attached to the main channel is DCE, strap to NORMAL. If the equipment is DTE, strap to FROM EXT DTE.
3.Synchronization on the equipment attached to sub-channel 1.
•Main channel: Equipment attached to the main channel should be set to external clock.
•
•
•BIT RATE rotary switch: Set BRI to position 7 (CLK1).
•Jumper J7: If the equipment attached to the
NOTE: Synchronization on
4.Synchronization on equipment attached to any
•Main channel: Equipment attached to the main channel can be set to internal or external clock.
•
9