EDS Series Factory Sealed | Cl. I, Div. 1 & 2, Groups B*, C, D | Explosionproof | 2C |
Manual Motor Starting Switches | Cl. II, Div. 1, Groups E, F, G |
| |
Cl. II, Div. 2, Groups F, G | Raintight |
| |
and Enclosures | Cl. III | Wet Locations |
|
NEMA 3, 7B*CD, 9EFG
Ordering Information
With
Maximum HP Ratings |
| |||
|
| |||
Poles | Volts AC | Votts DC | Cat. # | |
|
|
|
| |
1 | 1 hp |
| A B BUL 600 TOX4 | |
2 | 1 hp | 3/4 hp | A B BUL 600 TOX5 | |
| Hub |
|
| |
Poles | Size in. | Dead end Cat. # | Through feed Cat. # | |
|
|
| ||
Single Gang | EDS2199 ➀ | EDSC2199 ➀ | ||
1 | 3/4 | |||
1 | EDS3199 ➀ | EDSC3199 ➀ | ||
| ||||
2 | 3/4 | EDS21100 ➀ | EDSC21100 ➀ | |
1 | EDS31100 ➀ | EDSC31100 ➀ | ||
| ||||
|
|
| ||
Two Gang | EDS2299 ➀ | EDSC2299 ➀ | ||
1 | 3/4 | |||
1 | EDS3299 ➀ | EDSC3299 ➀ | ||
| ||||
2 | 3/4 | EDS22100 ➀ | EDSC22100 ➀ | |
1 | EDS32100 ➀ | EDSC32100 ➀ | ||
|
With General Electric Switches
Maximum HP Ratings |
|
|
|
| ||
| 115 | 230 |
|
| ||
Poles | Volts AC | Votts DC | Votts DC | Cat. # | ||
|
|
|
|
| ||
1 | 1 hp | 1 hp | 1/4 hp | GE CR101 Y |
| |
2 | 1 hp | 1 hp | 1 hp | GE CR101 H | ||
| Hub Size |
|
|
|
| |
Poles | in. | Dead end Cat. # Through feed Cat. # | ||||
|
|
|
|
| ||
Single Gang | EDS21093 ➀ | EDSC21093 ➀ | ||||
1 | 3/4 | |||||
1 | EDS31093 ➀ | EDSC31093 ➀ | ||||
| ||||||
2 | 3/4 | EDS21094 ➀ | EDSC21094 ➀ | |||
1 | EDS31094 ➀ | EDSC31094 ➀ | ||||
| ||||||
|
|
|
|
| ||
Two Gang | EDS22093 ➀ | EDSC22093 ➀ | ||||
1 | 3/4 | |||||
1 | EDS32093 ➀ | EDSC32093 ➀ | ||||
| ||||||
2 | 3/4 | EDS22094 ➀ | EDSC22094 ➀ | |||
1 | EDS32094 ➀ | EDSC32094 ➀ | ||||
|
2C
Heater Table |
|
| Heater Table (General Electric) |
| ||||
Max. Motor |
| Max. Motor |
|
| Max. Motor |
| Max. Motor |
|
|
|
| ||||||
Amps | Symbol Number | Amps | Symbol Number |
| Amps | Symbol Number | Amps | Symbol Number |
|
|
|
|
|
|
|
|
|
0.17 | P1 | 2.92 | P22 | .48 | G2 | 3.01 | G22 | |
0.21 | P2 | 3.09 | P23 | .53 | G3 | 3.27 | G23 | |
0.25 | P3 | 3.32 | P24 | .58 | G4 | 3.56 | G24 | |
0.32 | P4 | 3.77 | P25 | .65 | G5 | 3.88 | G25 | |
0.39 | P5 | 4.16 | P26 | .71 | G6 | 4.22 | G26 | |
0.46 | P6 | 4.51 | P27 | .78 | G7 | 4.60 | G27 | |
0.57 | P7 | 4.93 | P28 | .86 | G8 | 5.00 | G28 | |
0.71 | P8 | 5.43 | P29 | .95 | G9 | 5.43 | G29 | |
0.79 | P9 | 6.03 | P30 | 1.04 | G10 | 5.90 | G30 | |
0.87 | P10 | 6.83 | P31 | 1.14 | G11 | 6.41 | G31 | |
0.98 | P11 | 7.72 | P32 | 1.25 | G12 | 6.98 | G32 | |
1.08 | P12 | 8.24 | P33 | 1.37 | G13 | 7.60 | G33 | |
1.19 | P13 | 8.9 | P34 | 1.49 | G14 | 8.25 | G34 | |
1.30 | P14 | 9.6 | P35 | 1.63 | G15 | 8.95 | G35 | |
1.43 | P15 | 10.8 | P36 | 1.78 | G16 | 9.75 | G36 | |
1.58 | P16 | 12.0 | P37 | 1.95 | G17 | 10.6 | G37 | |
1.75 | P17 | 13.5 | P38 | 2.13 | G18 | 11.4 | G38 | |
1.88 | P18 | 15.2 | P39 | 2.32 | G19 | 12.5 | G39 | |
2.13 | P19 |
|
| 2.53 | G20 | 13.6 | G40 | |
2.40 | P20 |
|
| 2.76 | G21 | 14.8 | G41 | |
2.58 | P21 |
|
|
|
|
| 16.0 | G42 |
➀Includes one interchangeable heater. Select heater from the table below individual listings and use symbol number as second section of the Cat. No. Example:
These heaters are for motors rated 40°C continuously. For motors rated 50°C or 55°C, multiply full load motor current by 0.9 and use this value to select heaters. Symbol 0 (zero) must be used to indicate heater omitted.
*Add GB suffix. Seals must be installed within 11/2" of each conduit opening for Group B usage.