RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS*

5.If you are using one extension cord for more than one tool, add the nameplate amperes and use the sum to determine the required minimum cord size.

(See Figure C.)

6.If you are using an extension cord outdoors, make sure it is marked with the suffix “W-A” (“W” in Canada) to indicate it is acceptable for outdoor use.

7.Make sure your extension cord is properly wired and in good electrical condition. Al- ways replace a damaged extension cord or have it repaired by a qualified electrician before using it.

8.Protect your extension cords from sharp objects, excessive heat, and damp or wet areas.

RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS*

(120 or 240 VOLT)

NAMEPLATE

 

 

 

 

EXTENSION CORD LENGTH

 

AMPERES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(at full load)

25 Feet

 

50 Feet

 

75 Feet

 

100 Feet

150 Feet

0 – 2.0

18

 

18

 

18

 

18

16

 

 

 

 

 

 

 

 

 

 

 

 

 

2.1

– 3.4

18

 

18

 

18

 

16

14

 

 

 

 

 

 

 

 

 

 

 

 

 

3.5

– 5.0

18

 

18

 

16

 

14

12

 

 

 

 

 

 

 

 

 

 

 

 

 

5.1

– 7.0

18

 

16

 

14

 

12

12

 

 

 

 

 

 

 

 

 

 

 

 

7.1 – 12.0

18

 

14

 

12

 

10

-

 

 

 

 

 

 

 

 

 

 

 

 

 

12.1

– 16.0

14

 

12

 

10

 

-

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

16.1

– 20.0

12

 

10

 

-

 

-

 

-

 

 

 

 

 

 

 

 

 

 

FIGURE C

* Based on limiting the line voltage drop to five volts at 150% of the rated amperes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Symbology

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Double Insulated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Canadian Standards Association

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Underwriters Laboratories, Inc.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V~

Volts Alternating Current

 

 

 

 

 

 

 

A

Amperes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SKU 93188

For technical questions, please call 1-800-444-3353

Page 8

Page 8
Image 8
Chicago Electric 93188 manual Nameplate, Extension Cord Length, Feet, Symbology, at full load, Amperes, See Figure C