Atlona AT-PRO2HD88M user manual Edid Set Up

Page 10

EDID Set Up

The final set up for the Matrix Switcher is for the EDID. When the matrix is completely connected and turned on it will load the default EDID, which is the highest common native resolution of the devices. (i.e. With devices connected that range from 720p, 1080p, 2 channel audio, multi-channel audio and 3D, the default resolution will be 720p. Multi-channel audio and 3D are not available on default unless all devices have these features.)

There are two options when setting up EDID: Default and Copy. In order to have any options other than default different EDIDs must first be copied. The AT-PRO2HD88M can copy up to 8 EDIDs to memory.

To save EDIDs follow the LCD on screen prompts of the switcher choosing option 1.

home screen

AT-PRO2HD88M Select Input Number

--->

Select function option

--->

 

 

 

 

1 to copy up to 8 EDIDs

2 to choose input EDID

--->

Select output to copy Press Enter

Copy from output # Save to Memory (1-8) #

----->

Press Enter to Confirm

To load a saved EDID follow the on screen instructions of the Matrix LCD choosing option 2.

home screen

AT-PRO2HD88M Select Input Number

----->Select function option

----->

1 to copy up to 8 EDIDs

2 to choose input EDID

----->

Input #

Select an input port

Input # Press Enter

Current: Default

---->

 

 

 

--->

Input: # Mode:

EDID Status screens

---->

 

 

1. Default 2. Saved EDID

 

 

 

 

 

 

 

Input # Press Enter

 

 

 

Current: Saved EDID

 

 

 

 

 

 

 

--->

Input: # Select saved EDID memory 1 thru 8

--->

Use EDID Memory # + Enter (EDID info here)

The AT-PRO2HD88M at this time should be fully set up and ready to use.

Toll free: 1-877-536-3976

10

atlona.com

Local: 1-408-962-0515

Image 10
Contents Atlona Hdmi 8 by 8 Matrix Switcher Over CAT5e/6/7 Table of Contents Features Package ContentsIntroduction Remote Control SpecificationsBefore You Start Panel Description Front PanelBack Panel Connection and Installation 3rd Party Controller Set UpIR Remote Control Set Up Matrix I/O Control Edid Set Up RS-232 CommandConnection RS-232 Set Up Baud RateCSpara38400,8,0,1 Resetting to factory settings Updating firmwareSafeguards Safety InformationPrecautions Warranty Atlona Product Registration