Atlona AT-PRO2HD1616M user manual RS-232 Set Up, Baud Rate

Page 12

RS-232 Set Up

To set up the RS-232 hyperterminal (if not using 3rd party software) the first thing needed is to find the RS-232 communications port under the computer’s device manager. Once there right click the port and select properties. Under the properties menu select the port settings tab and update the menu to the matrix default: Bits Per Second: 115200, Data Bits: 8, Parity: None, Stop Bits: 1 and Flow Control: None.

Baud Rate

To change the baud rate of the matrix or the receivers (i.e. AT-PRO2HDREC or AT-PRO21616M-RX) an RS-232 hyperterminal will be needed. Once the RS-232 hyperterminal is set up changing the baud rate will be done with a command line. The baud rate for the matrix is for matrix control and the receiver baud rate is for control of the RS-232 device in the zone being altered.

Note: Baud Rate must be only 2400, 4800, 9600, 19200, 38400, 57600, or 115200

Command for Matrix baud rate

CSpara[baudrate,data-length,parity,stop-bit](data, parity, and stop for matrix must be 8,0,1)

For example if you wish to change the baud rate to 38400 the command would look like this:

CSpara[38400,8,0,1]

Toll free: 1-877-536-3976

12

atlona.com

Local: 1-408-962-0515

Image 12
Contents Atlona Hdmi 16 by 16 Matrix Switcher Over CAT5e/6 Table of Contents Package Contents FeaturesIntroduction Specifications Remote ControlBefore You Start Panel Description Front PanelBack Panel Connection and Installation 3rd Party Controller Set UpIR Remote Control Set Up Matrix I/O Control Edid Set Up Command RS-232Connection RS-232 Set Up Baud RateRS232para619200,8,1,1 Resetting to factory settings Updating firmwareSafety Information Warranty Atlona Product Registration