Star Micronics IS-NP192 user manual Switch 2 Parity Check, Switch 3 Parity, Switch 4 Protocol

Page 8

Switch 2: Parity Check

This switch specifies whether or not a parity check should be performed on the data.

Parity Check

SW2

DOS Setting

Disabled

ON

Disabled

Enabled

OFF

Enabled

Switch 3: Parity

This switch specifies the parity as non, odd, or even.

Parity

SW3

DOS Setting

Odd

ON

O

Even

OFF

E

Switch 4: Protocol

Protocol, which is sometimes referred to as “handshaking,” is the com- munications convention that is used to allow the printer and computer to regulated the flow of data. DTR is the most commonly used proto- col.

Protocol

SW4

DOS Setting

DTR

ON

DTR

XON/XOFF

OFF

XON/XOFF

Switches 5, 6: Not used

BANK B

Switch 1, 2, 3: Baud Rate

The baud rate is the speed, in bits per second, that the printer sends data to the computer. The common setting is 9600 or 19200.

6

Image 8
Contents Serial Interface Unit Модуль Последовательного Интерфейса Пðåäóïðåæäåíèå English Unpacking InstallationSerial Interface Unit Installing the serial interface unit Connecting a serial cable Switch 1 Data Length Setting the printer’s Electronic DIP switches EDSEDS-2 Settings Switch 2 Parity Check Switch 3 ParitySwitch 4 Protocol Switches 5, 6 Not usedSwitches 4, 5, 6 Not used Software Settings Setting up a serial connection on an MS-DOS computerTechnical Specifications Input Connector Signals and FunctionsРóññêèé Иíñòàëëяöèя Мîäóëü ïîñëåäîâàòåëüíîãî èíòåðôåéñàРàñïàêîâêà Иíñòàëëяöèя ìîäóëя ïîñëåäîâàòåëüíîãî èíòåðôåéñà Пîäñîåäèíåíèå ïîñëåäîâàòåëüíîãî êàáåëя Пåðåêëþ÷àòåëü 1 Дëèíà äàííûõ Уñòàíîâêà ýëåêòðîííûõ ДИП-ïåðåêëþ÷àòåëåé ïðèíòåðà EDSВûñòàâêè ðåæèìà EDS-2 Пåðåêëþ÷àòåëü 2 Пðîâåðêà ÷åòíîñòè Пåðåêëþ÷àòåëü 3 ЧåòíîñòüПåðåêëþ÷àòåëü 4 Пðîòîêîë Пåðåêëþ÷àòåëè 5,6 Нå èñïîëüçóþòñяУñòàíîâêà ïîñëåäîâàòåëüíîãî ñîåäèíåíèя íà MS-DOS êîìïüþòåðå Тåõíè÷åñêèå óñëîâèя Вõîä Сèãíàëû è ôóíêöèè ñîåäèíèòåëяPage KEI International Corporation