Seiko Instruments G1216B1N000 user manual Operating Instructions, Mpu, CS1 CS2

Page 17

AN.No.G1216B1N000-3D0E

3.OPERATING INSTRUCTIONS

3.1Terminal Functions

Table 1 Terminal Functions

Signal

QTY

I/O

Destination

 

 

 

Functions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DB0 to DB7

8

I/O

MPU

Common terminal for tristate input and output, and data bus.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

1

Input

MPU

Enable

 

 

 

 

 

 

 

 

 

 

 

 

Write (R/W=0):Latches data of DB0 to DB7 at the fall of E.

 

 

 

 

Read (R/W=1):Outputs data to DB0 to DB7 while “E” keeps a

 

 

 

 

high level.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R/W

1

Input

MPU

Read/Write selection

 

 

 

 

 

 

 

 

 

 

R/W=1: When E=1 and CS1=0 or CS2=0, the data is output

 

 

 

 

 

to DB0 to DB7 and read is available by MPU.

 

 

 

 

R/W=0: When CS1=0 or CS2=0, DB0 to DB7 are ready for

 

 

 

 

 

receiving the input.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D/I

1

Input

MPU

Data/Instruction selection

 

 

 

 

 

 

 

 

 

 

D/I=1: Indicates that the data in DB0 to DB7 is the display

 

 

 

 

 

data.

 

 

 

 

 

 

 

 

 

 

 

 

D/I=0: Indicates that the data in DB0 to DB7 is the instruction

 

 

 

 

 

code.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CS1, CS2

2

Input

MPU

Chip select input. Data input and output is possible under

the following status:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LCM display screen

 

 

 

 

 

Terminal No.

 

CS1

 

CS2

 

 

 

 

 

 

 

 

 

 

 

CS1

 

CS2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Status

 

0

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CS1: Controls the LCM left half display screen (SEG1 to

 

 

 

 

SEG64).

 

 

 

 

 

 

 

 

 

 

 

 

CS2: Controls the LCM right half display screen (SEG65 to

 

 

 

 

SEG128).

 

 

 

 

 

 

 

 

RST

1

Input

MPU

Reset signal

 

 

 

 

 

 

 

 

 

 

 

 

Setting the RST signal to a low level allows for initial setup.

 

 

 

 

 

(1) ON /OFF register: 0 setup (display OFF)

 

 

 

 

 

 

 

 

(2) Display start line register: 0 line setup (display starts

 

 

 

 

 

from 0 line)

 

 

 

 

 

 

 

 

 

 

 

 

The setup status is retained until the status is changed by an

 

 

 

 

instruction after reset is released.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VDD

1

 

Power

Power terminal for logic (+5 V)

 

 

 

 

 

VSS

1

 

Power

GND terminal (0 V)

 

 

 

 

 

 

VLC

1

 

Power

Power terminal for LC drive

 

 

 

 

 

 

LEDA

1

 

Power

LED backlight anode terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEDC

1

 

Power

LED backlight cathode terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FGND

1

￿

￿

Frame ground1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1FGND terminal is connected to the metallic frame of the module. Use this terminal when grounding the frame.

- 14 -

Image 17
Contents AN.No.G1216B1N000-3D0E USER’S ManualCopyright 1993 by Seiko Instruments Inc Contents General Symbol Conditions Min Typ Max Unit Input High +80 Temperature StoragePower supply voltage Voltage25 C Vopr=13.0 Viewing angle Min Typ Max Unit Remark∅ = 25 C Vopr=13.0 Contrast 25 C Vopr=13.0−20 To +70 Storage temp. range AN.No.G1216B1N000-3D0E Definition of response timeNumber of LED LedaChips=20 LedcDB1 DB0DB2 DB3V c, V d, V f Circuit ConfigurationCS2 CS1 FRM CS R/WLSB MSBBusy Page COM2 COM1COM3 COM4Operational Amplifier Bias R2= 9 4 R1= 5 R1 CS1 CS2 Operating InstructionsMPU 140 450To DB7 Test point RL = 2.4 k = 11 kRise time 200 Reset timeD/I FunctionDetailed explanation Display ON/OFF Code DB7 DB0 AN.No.G1216B1N000-3D0E Display start line CodeDisplay start line=0 Display start line=1 Display start line =2 Display start line=3AN.No.G1216B1N000-3D0E Address page set Code Display Data RAM Address ConfigurationReset =10 k Ω Voltage V opr 13.5 13.0 12.5 11.5 10.5=1.2 k Ω Variable resistor=LED forward voltage =Input voltage power voltageV=Allowable LED forward current a Leda LedcZ80 PIO MPU Connection DiagramD0 to D7 A0 to A7 DB0 to DB7 A0 to A15 Decoder Iorq RST CS1Precautions 11, 12, 17 9, 11, 12, 17, 18, 19LC drive voltage 10, 16, 17Seiko Instruments Inc