Xantrex Technology RS232-HPD manual Specifications, Models 15-4 20-3 30-2 60-1 120-0.5 250-0.25

Page 15

Features and Specifications

Specifications

Specifications

The specifications in this section are warranted at 25°C ±5°C unless otherwise specified. All specifications are subject to change without notice.

Table 1.1 Specifications for XT 60 W Series Supply with RS-232 Interface Installed

Models

7-6

15-4

20-3

30-2

60-1

120-0.5

250-0.25

Program Resolution

 

 

 

 

 

 

 

Voltage

1.1mV

2.4mV

3.1mV

4.7mV

9.3mV

17mV

34mV

Current

1.0mA

0.6mA

0.5mA

0.3mA

0.2mA

0.1mA

0.08mA

OVP

1.0mV

2.4mV

3.1mV

4.7mV

9.3mV

17mV

34mV

Program Accuracy1

10mV

20mV

20mV

30mV

200mV

400mV

800mV

Voltage

 

±0.1%

±0.1%

±0.15%

±0.15%

±0.15%

±0.15%

±0.15%

Current

110mA

70mA

50mA

40mA

26mA

13mA

7mA

 

±0.15%

±0.15%

±0.15%

±0.15%

±0.2%

±0.2%

±0.2%

OVP

70mV

150mV

200mV

300mV

600mV

1.2V

2.4V

Readback Resolution

 

 

 

 

 

 

 

Voltage

1.1mV

2.4mV

3.1mV

4.7mV

9.3mV

17mV

34mV

Current

1.0mA

0.6mA

0.5mA

0.3mA

0.2mA

0.1mA

0.08mA

Readback Accuracy1

 

 

 

 

 

 

 

Voltage

10mV

10mV

10mV

15mV

35mV

70mV

140mV

 

±0.15%

±0.1%

±0.1%

±0.1%

±0.15%

±0.15%

±0.15%

Current

110mA

70mA

50mA

40mA

26mA

13mA

7mA

 

±0.15%

±0.15%

±0.15%

±0.15%

±0.2%

±0.2%

±0.2%

1.Apply accuracy specifications according to the following voltage program accuracy example: Set a model XT 15-4 power supply to 10 volts.

The expected result will be within the range of 10 volts ± 20mV ± 0.1% of the set voltage of 10 volts.

Release 1.1

13

Image 15
Contents RS232-HPD Page Internal RS-232 Interface for XT 60 Watt HPD 300 Watt Series Phone 604 422 Toll Free North America 800 667 Fax 604 421 How do you get service?What does this warranty not cover? Disclaimer Product Information About Your Power Supply Release Release 1.1Model Number Serial Number Purchased From Purchase Date Supply SafetyInstallation and Configuration Main SectionsManual Revisions About This Manual Contents Contents Description Features and SpecificationsReadback Functions Features and FunctionsFeatures Features and SpecificationsModels 15-4 20-3 30-2 60-1 120-0.5 250-0.25 SpecificationsModels 15-20 30-10 60-5 Initial Inspection IntroductionPower Supply Front Panel with RS-232 Interface Installed See next page for designation descriptions Open See .13, on LED IndicatorsBasic Setup Procedure Flow Control Selection on See Connector J7 User SignalsSee Power Supply Settings on See Baud Rate Selection onBaud Rate CommunicationsXON Switch Setting Condition Flow Switch Setting ConditionJumper Connections RS-232 Connector Pin Jumper J7 Connections RS-232 Connector Pin Power Supply DCE Host Computer DTE Pin connectorJumper J95 Position Operating State Switch Position Power on resultsCondition Default Settings 60 W 7-6 Model Example RS-232 Connection RS-232 Connector J4 Pinouts default configurationParameter Setting Power Supply Settings13 OVP Control Mode Selection User Options and SettingsHigh OFF LOW User Signals J7 Connector User SignalsJ7 User Signal Connector Circuit Block Diagram J7 User Cable with Ferrite Block Installation and Configuration RS-232 Operation Command SyntaxVout OperationFormat Floating Number Definition Example Description FormExample Command Description Command SummaryAUXA? Cmode Auxa 1 on Command ReferenceRegister. See Error Codes on Returns the supply’s present foldback setting Command on Status, and Fault Registers on Registers on Accumulated Status, Status, and Fault Registers onReturns the supply’s soft voltage limit setting Accumulated Status, Status, and Fault Registers REM Condition Mnemonic Bit Position Bit WeightError # Error Identification Explanation Error CodesLEDs TroubleshootingCalibration Voltage Voltage Mode CalibrationSetup Voltage Program Calibration ProcedureVoltage Readback Calibration Procedure Current Mode Calibration Current Calibration SetupCurrent Program Calibration Procedure Current Readback Calibration Procedure Over Voltage Protection OVP Calibration Page Xantrex Technology Inc

RS232-XT, RS232-HPD specifications

Xantrex Technology has made significant strides in the field of power electronics, particularly with its RS232-HPD and RS232-XT communication interfaces. These devices are designed to enhance the efficiency and reliability of power management systems, providing users with advanced features and robust technologies.

The RS232-HPD (High Power Device) is optimized for high-performance applications, enabling seamless communication between power devices and control systems. One of its key features is its compatibility with a wide range of power inverters and converters, making it suitable for diverse applications including renewable energy systems, industrial automation, and marine power solutions. The RS232-HPD supports higher baud rates, allowing for faster data transmission and improved responsiveness in monitoring and control operations.

On the other hand, the RS232-XT (Extended Temperature) variant takes durability to the next level. It is designed to operate in extreme temperature conditions, which is crucial for applications located in harsh environments. The RS232-XT retains all the fundamental benefits of the RS232-HPD while providing additional resilience against temperature fluctuations. This feature is particularly advantageous for outdoor installations, where temperature extremes can impact performance and reliability.

Both the RS232-HPD and RS232-XT are equipped with extensive diagnostic tools that enable users to monitor system performance in real-time. These tools include error detection algorithms and status monitoring, which help in identifying potential issues before they escalate. The user-friendly interface simplifies the setup process, making it accessible for both experienced users and those new to power system management.

A standout characteristic of these interfaces is their robust communication protocols, designed to ensure secure data transmission. With built-in protection against common electrical anomalies, such as voltage spikes and electromagnetic interference, the Xantrex RS232 series guarantees uninterrupted operation and data integrity.

Integration with existing systems is straightforward, thanks to their standard RS232 connectivity. This compatibility makes them ideal for retrofitting older systems without the need for significant infrastructure changes.

In conclusion, Xantrex Technology's RS232-HPD and RS232-XT interfaces are exemplary solutions for advanced power management, offering high performance, durability, and ease of use. Their innovative features and robust technologies solidify Xantrex's position as a leader in the power electronics market. Whether for residential, commercial, or industrial applications, these devices stand ready to deliver efficient and reliable power management solutions.