Xantrex Technology Solar 400 manual 1Troubleshooting reference

Page 53

 

 

 

 

 

Troubleshooting Reference

 

 

 

 

 

 

Table 5-1Troubleshooting reference

 

 

 

Problem

 

Possible Cause

 

Solution

 

 

 

 

 

 

 

 

 

 

Digital display

 

The appliance

 

Unplug the appliance and confirm

 

shows E04 and

 

connected to the AC

 

that the appliance’s power

 

alarm sounds.

 

socket (or DC socket)

 

requirement is 320 W or less (144 W

 

 

 

exceeds the capability

 

or less) before attempting to restart

 

 

 

of the Powerpack

 

the appliance.

 

 

 

Solar 400.

 

 

 

 

 

 

 

 

 

Digital display

 

The appliance

 

Unplug and check the appliance.

 

shows E05 and

 

connected to the AC

 

 

 

alarm sounds.

 

socket has a short

 

 

 

 

 

circuit.

 

 

 

 

 

 

 

 

 

Digital display

 

Internal battery

 

Unplug all appliances and start

 

shows E07 and

 

voltage falls below the

 

recharging the Powerpack Solar 400.

 

alarm sounds.

 

operational voltage

 

 

 

 

 

capacity.

 

 

 

 

 

 

 

 

 

Measured AC

 

Use of an

 

The modified sine wave (MSW)

 

output voltage

 

average-reading AC

 

output of the Powerpack Solar 400

 

is too low.

 

voltmeter to read

 

requires a true RMS reading meter,

 

 

 

output voltage.

 

such as the Fluke 87 series, for

 

 

 

 

 

accurate measurement.

 

 

 

 

 

A typical reading on a non-true RMS

 

 

 

 

 

meter should show between 98 Vac

 

 

 

 

 

to 120 Vac.

 

 

 

Internal battery is

 

Verify battery status and recharge the

 

 

 

almost fully

 

Powerpack Solar 400 as necessary.

 

 

 

discharged.

 

“Battery Charge %” reading on the

 

 

 

 

 

 

 

 

 

 

digital display is only accurate when

 

 

 

 

 

the Powerpack Solar 400 has been

 

 

 

 

 

disconnected from all appliances and

 

 

 

 

 

all charging sources for 15 minutes.

 

 

 

 

 

 

975-0328-01-01

37

Image 53
Contents Owner’s Guide XPower Powerpack SolarDate and Revision Conventions Used PurposeRelated Information Important Safety Instructions Important Safety Instructions Precautions for Using Rechargeable Appliances First Aid If Battery Acid Contacts EyesContents Maintenance Warranty and Return Information TroubleshootingSpecifications Page Tables Xii Figures Xiv Introduction About the Powerpack SolarComprehensive Protection Automatic OverloadOverheating Low Battery ProtectionContents FeaturesFront and Side Panels Powerpack Solar 400 FeaturesControl Panel and Display Control Panel and DisplayFeature Power Socket Side PanelSolar Panel Component Solar Panel ComponentsBackside Panel AccessoriesOperating Conditions and Guidelines OperationChoosing a Location Dry Cool Ventilated Safe Protected from battery gasesImportant Charge Before Use Recharging the Powerpack Solar 400 BatteryCharging with the AC Charger Powerpack Solar 400 AC Charging Feature1Charging with AC Power Charging with the DC-to-DC Accessory Cable 2Charging with DC Power Recharging with a Generator’s Regulated 12 Vdc Outlet To reconnect the solar panel to the unit Recharging From the Solar PanelTo recharge with a solar panel Interpreting Display Codes Checking Battery and AC StatusRequired How to Condition Action Interpreting Display Codes Important Know the size of the loads AC AppliancesOperating AC Appliances Low-Battery AlarmOverload Protection 2Typical 12 V DC Appliances and Run Times Vdc Appliances7Operating DC Appliances Operating DC Appliances3Typical USB Devices and Charge Times USB DevicesCharging Devices via the USB Port Low Battery Alarm9LED Lamp Controls Using the LED Lamps10 Back Stand Using the Back StandBattery Maintenance MaintenanceSolar Panel Maintenance Recycling Battery LifeBattery Maintenance Page Common Problems TroubleshootingBuzz in Audio Equipment Television Interference1Troubleshooting reference Troubleshooting Reference1Troubleshooting reference 1Troubleshooting reference Display Error Codes Page Electrical Specifications SpecificationsDC Power Section Solar Panel Section Physical SpecificationsPage Warranty Warranty and Return InformationProduct DisclaimerExclusions Return Material Authorization PolicyReturn Procedure Out of Warranty Service Information About Your System

Solar 400 specifications

Xantrex Technology has established itself as a leader in innovative energy solutions, and its Solar 400 model exemplifies this commitment to quality and efficiency. Ideal for residential and commercial applications, the Xantrex Solar 400 plays a pivotal role in harnessing solar energy, making it an indispensable component of modern renewable energy systems.

One of the standout features of the Xantrex Solar 400 is its remarkable energy conversion efficiency. The inverter is designed to maximize the energy harvested from solar panels, converting direct current (DC) generated by the panels into alternating current (AC) that can be used in homes or fed back into the grid. This high conversion rate ensures that users get the most out of their solar investments.

The device incorporates advanced Maximum Power Point Tracking (MPPT) technology, which optimizes energy capture even during partial shading or varying sunlight conditions. By continuously adjusting the operating point of the solar panels, the Solar 400 ensures that the system operates at its peak performance throughout the day.

Another significant characteristic of the Xantrex Solar 400 is its robust design and durability. Built to withstand various environmental conditions, the inverter features a weather-resistant casing that protects the internal components from moisture and dust. This resilience extends the lifespan and reliability of the system, ensuring installation in a variety of settings.

User-friendly functionality is a hallmark of the Solar 400. The inverter is equipped with a user-friendly interface that allows easy monitoring of system performance. Additionally, it supports remote monitoring capabilities, enabling users to track energy production and system status from anywhere, enhancing convenience and troubleshooting efficiency.

Safety features are prioritized in the design of the Xantrex Solar 400. The inverter includes multiple protection mechanisms, including over-voltage, over-temperature, and short-circuit protections, ensuring safe operation in any scenario. This ensures that both users and equipment are safeguarded.

Finally, the Xantrex Solar 400 is compatible with a wide range of solar panels and battery systems, making it a versatile choice for various energy solutions. Its scalability allows for easy integration into both new installations and existing systems, providing flexibility for users looking to expand their renewable energy capabilities.

In summary, the Xantrex Technology Solar 400 stands out as a reliable, efficient, and user-friendly inverter, making it an excellent choice for anyone looking to harness solar energy effectively. With features like MPPT technology, durability, safety mechanisms, and compatibility with numerous systems, it is a prudent investment in sustainable energy.