Xantrex Technology IP1012 AL manual Inverter/charger Features, About the unit

Page 12

Introduction

Inverter/charger Features

Features

The IP1012 AL is an ignition-protected, modified sine wave inverter/

 

charger weighing about 40 pounds (18 kg). It is sealed, dust and water

 

resistant, and can be mounted where it may be exposed to the elements.

 

Figure 1-1 shows its main features.

 

Consult Appendix A, “Specifications” for more detailed information

 

about the unit.

7

6

1

5

2

34

Figure 1-1Features of the inverter/charger

1–2

975-0337-01-01

Image 12
Contents IP1012 AL Inverter/Charger with Ignition Protection Page IP1012 AL Inverter/ Charger with Ignition Protection Date and Revision Purpose ScopeAudience OrganizationConventions Used Related InformationFollowing conventions are used in this guide Important Safety Information General PrecautionsPrecautions When Working With Batteries Precautions for Using Rechargeable Devices Contents Troubleshooting SpecificationsCommon Problems Blinking Lights on the Remote Switch Introduction Inverter/charger Features About the unitOperating Features Feature DescriptionIntroduction Operation Planning for AC Loads Type of LoadsAmbient Temperature Conditions or cabin heat from heatersWatts continuous Calculating Size of an AC Load Planning for AC Loads Appliance Watts Minutes Hours Running the Alternator While Operating AC and DC Loads OverloadedOperation Using the Remote Switch Switch positionLights will behave like this FloatRunning in Extremes Of Hot or Cold Temperatures Operating the Inverter/ChargerTurning the Inverter On and Running Loads Restarting After a ShutdownBattery Charging Using ShorepowerMiscellaneous Hints AutomaticMaintenance Maintaining the Inverter/charger Checking TerminalsDisconnecting and Connecting the Batteries DisconnectingConnecting Replacing the Fuse To replace the fuse Lift the fuse cover off as shown in FigureRemoving and Reconnecting AC Cables To remove the AC cablesTroubleshooting Troubleshooting Common ProblemsBlinking Lights on the Remote Switch Troubleshooting reference2Charger indicator blink patterns Specifications Physical Specifications Physical specificationsInverter Specifications Charger Specifications Shutdowns and RestartsTransfer and General Specifications Transfer and general specificationsRating Curves and Charging Profiles Time minutesFigure A-3Three-stage charging profile Page Index IX-2 975-0337-01-01 Warranty and Return Information WarrantyDisclaimer ProductReturn Material Authorization Policy Return ProcedureExclusions Out of Warranty Service Information About Your SystemSerial Number Product Number Purchased From Purchase DatePage Xantrex Technology Inc
Related manuals
Manual 52 pages 11.23 Kb