Xantrex Technology IP1012 AL Blinking Lights on the Remote Switch, Troubleshooting reference

Page 35

 

 

 

 

Troubleshooting

 

 

 

 

 

 

Table 4-1

Troubleshooting reference (Continued)

 

 

 

Symptom

 

Possible Problem

 

Remedy

 

 

 

 

 

 

 

Loads stop operating without

Too many appliances have

 

Reduce the number of loads.

warning after they have been

reduced the battery voltage to

 

Allow the inverter to cool and

running.

 

shutdown level.

 

restart. Recharge the batteries.

Shorepower is not connected.

 

 

 

 

 

 

Ambient temperature is too

 

Disconnect appliances and let the

 

 

high.

 

unit cool down.

 

 

 

 

 

The inverter will not work

Remote switch may be

 

Check that the remote switch is

even after toggling the switch,

disconnected at the unit

 

firmly connected.

charging the batteries, and

 

 

 

 

letting the unit cool down.

Fuse on the unit (shown in

 

Replace the fuse or return the unit

 

 

 

 

 

Figure 1-1) may have blown

 

to an authorized Xantrex dealer.

 

 

 

 

 

AC voltage at receptacles

Wrong type of voltmeter being

 

Use a true RMS meter

reads low.

 

used.

 

 

 

 

 

 

 

 

In inverter mode, times to

Bad battery cable or corroded

 

Check the cables and connectors

shutdown are getting shorter

battery terminals.

 

 

 

for the same kind of AC load

Batteries too old or damaged.

 

Replace the batteries.

 

 

 

 

 

 

Blinking Lights on the Remote Switch

You may encounter different sequences of blinking lights when the inverter is enabled (i.e., switch is on) or the unit is charging. Light sequences are described as follows:

Blink Level 1

Fast blink

Light is on for 1/4 second and off for

 

 

1/4 second

 

 

 

Blink Level 2

Slow blink

Light is on for 1/2 second and off for

 

 

1/2 second

 

 

 

Blink Level 3

Very slow blink

Light is on for one second and off for

 

 

one second

 

 

 

975-0337-01-01

4–3

Image 35
Contents IP1012 AL Inverter/Charger with Ignition Protection Page IP1012 AL Inverter/ Charger with Ignition Protection Date and Revision Organization PurposeScope AudienceFollowing conventions are used in this guide Conventions UsedRelated Information General Precautions Important Safety InformationPrecautions for Using Rechargeable Devices Precautions When Working With BatteriesContents Common Problems Blinking Lights on the Remote Switch TroubleshootingSpecifications Introduction About the unit Inverter/charger FeaturesFeature Description Operating FeaturesIntroduction Operation Type of Loads Planning for AC LoadsWatts continuous Ambient TemperatureConditions or cabin heat from heaters Calculating Size of an AC Load Planning for AC Loads Appliance Watts Minutes Hours Overloaded Running the Alternator While Operating AC and DC LoadsOperation Switch position Using the Remote SwitchFloat Lights will behave like thisRestarting After a Shutdown Running in Extremes Of Hot or Cold TemperaturesOperating the Inverter/Charger Turning the Inverter On and Running LoadsAutomatic Battery ChargingUsing Shorepower Miscellaneous HintsMaintenance Checking Terminals Maintaining the Inverter/chargerConnecting Disconnecting and Connecting the BatteriesDisconnecting Replacing the Fuse Lift the fuse cover off as shown in Figure To replace the fuseTo remove the AC cables Removing and Reconnecting AC CablesTroubleshooting Common Problems TroubleshootingTroubleshooting reference Blinking Lights on the Remote Switch2Charger indicator blink patterns Specifications Physical specifications Physical SpecificationsInverter Specifications Shutdowns and Restarts Charger SpecificationsTransfer and general specifications Transfer and General SpecificationsTime minutes Rating Curves and Charging ProfilesFigure A-3Three-stage charging profile Page Index IX-2 975-0337-01-01 Warranty Warranty and Return InformationProduct DisclaimerExclusions Return Material Authorization PolicyReturn Procedure Purchased From Purchase Date Out of Warranty ServiceInformation About Your System Serial Number Product NumberPage Xantrex Technology Inc
Related manuals
Manual 52 pages 11.23 Kb

IP1012 AL specifications

The Xantrex Technology IP1012 AL is a high-performance inverter designed to meet the needs of mobile and off-grid applications. With its compact and lightweight design, the IP1012 AL is ideal for recreational vehicles, boats, and even remote cabins, providing a reliable source of power wherever it is needed. One of the standout features of this inverter is its ability to deliver a continuous output of 1000 watts, with a surge capacity of up to 2000 watts. This makes it capable of powering a range of devices, from laptops and televisions to small appliances and power tools.

The Xantrex IP1012 AL utilizes advanced sine wave technology, which produces a pure sine wave output that is essential for sensitive electronic equipment. This technology ensures that devices such as computers and medical equipment operate safely and efficiently, minimizing the risk of damage from power fluctuations. Additionally, the inverter is equipped with built-in safety features, including thermal shutdown protection, overload protection, and short circuit protection, ensuring that both the inverter and connected devices are safeguarded against potential electrical hazards.

Another key characteristic of the IP1012 AL is its user-friendly interface, featuring LED indicators that provide real-time information on the inverter's status and performance. The inverter also boasts a wide input voltage range, accommodating various battery types and configurations, making it versatile and adaptable for different applications. Its lightweight aluminum chassis further enhances its portability, making it a perfect choice for outdoor enthusiasts and those seeking a dependable power source for camping or hiking trips.

Furthermore, the Xantrex IP1012 AL is designed for efficiency, with a built-in energy-saving mode that reduces power consumption when the inverter is not in use. This feature prolongs battery life and maximizes the efficiency of the overall system. The inverter connects easily to battery banks, and its compact form factor allows for convenient installation in tight spaces.

In summary, the Xantrex Technology IP1012 AL is a powerful and reliable inverter that offers essential features for a variety of mobile and off-grid applications. Its advanced sine wave technology, safety features, user-friendly interface, and energy efficiency make it an excellent choice for anyone looking for dependable portable power. Whether you're a weekend warrior or a full-time RV traveler, the IP1012 AL ensures you have the energy you need when you need it.