TRENDnet v.92 PCI MODEM Appendix Modem Specifications, Appendix 2 Government compliance notices

Page 22

 

I206 V.92 PCI MODEM USER’S MANUAL

 

 

Appendix 1

Modem Specifications

Modulation standard

: V.92, V.90, K56 flex, V.34+, V.34, V.32bis, V.32, V.29, V.27ter, V.22bis,

 

V.23, V.22, V.21, V.17, Bell212/103

Compression

: V.42bis, MNP Class 5

Error Correction

: V.44, V.42, MNP Class 2-4

Host Interface

: PCI bus

FAX Group

: Group III

FAX Command

: EIA/TIA 578 class 1

Power

: 0.75 W max

Temperature

: 0 to 55 degrees C, operating; -20 to 75 degrees C, non-operating

Appendix 2 Government compliance notices

FCC compliance

This equipment complies with Part 68 of the FCC Rules. On this equipment is a label that contains, among other information, the FCC registration number and Ringer Equivalence Number (REN) for this equipment. You must, upon request, provide this information to your telephone company.

If your telephone equipment causes harm to the telephone network, the Telephone Company may discontinue your service temporarily. If possible, they will notify in advance. But, if advance notice isn’t practical, you will be notified as soon as possible. You will be informed of your right to file a complaint with the FCC.

Your telephone company may make changes in its facilities, equipment, operations, or procedures that could affect proper operation of your equipment. If they do, you will be notified in advance to give you an opportunity to maintain uninterrupted telephone service.

The FCC prohibits this equipment to be connected to party lines or coin-telephone service.

In the event that this equipment should fail to operate properly, disconnect the equipment from the phone line to determine if it is causing the problem. If the problem is with the equipment, discontinue use and contact your dealer or vendor.

Rev.1.00.2.1.57.75

- 22 -

Image 22
Contents Table of Content Contents of Package Hardware Installation ModelSection System Setup Setup instructions for Windows 98SE Select International Settings tab as shown in figure 2 Uninstall Modem from Windows 98SE Click Install/Uninstall tab and choose IntelR 537EP Modem3 Setup instructions for Windows Me I206 V.92 PCI Modem USER’S Manual 4 Uninstall Modem from Windows Me 5 Setup instructions for Windows I206 V.92 PCI Modem USER’S Manual I206 V.92 PCI Modem USER’S Manual I206 V.92 PCI Modem USER’S Manual 6 Uninstall Modem from Windows 7 Setup instructions for Windows XP Click on Continue anywayI206 V.92 PCI Modem USER’S Manual I206 V.92 PCI Modem USER’S Manual 8 Uninstall Modem from Windows XP Testing Your Modem Install Communication SoftwareProblem Modem dials but does not connect Possible solutions SectionProblem No dial tone Possible solutions Appendix 2 Government compliance notices Appendix Modem SpecificationsFCC compliance FCC Class B statement DOC compliance informationEuropean CTR 21 compliance

1206, v.92 PCI MODEM specifications

The TRENDnet v.92 PCI Modem, model 1206, offers users a reliable and efficient solution for dial-up internet connectivity. Designed for simplicity and performance, this modem is perfect for those seeking to maintain a stable Internet connection in areas where broadband may not be available.

One of the primary features of the TRENDnet v.92 PCI Modem is its compliance with the V.92 standard. This enables faster upload speeds and enhanced features compared to earlier technologies. The modem can achieve upload speeds of up to 48 Kbps and download speeds of up to 56 Kbps, making it a formidable option for users who still rely on dial-up connections.

The TRENDnet 1206 is a PCI-based modem, ensuring compatibility with a wide range of desktop computers. Installation is user-friendly, with the modem being housed on a PCI card that easily fits into most computer motherboards. This design allows for stable connectivity and efficient signal processing, contributing to overall performance improvements.

An important characteristic of the 1206 model is its built-in speakerphone feature, which allows users to manage calls directly through the modem. This is particularly useful for those who need to stay connected while using the internet. The modem also supports Caller ID functionality, providing users with important caller information that can help manage incoming communications effectively.

In terms of technologies, the TRENDnet v.92 PCI Modem utilizes advanced error correction and data compression techniques, such as MNP4 and V.42. These technologies help to ensure that the data being transmitted is accurate and efficient, reducing the likelihood of data loss during transfer and improving the overall user experience.

Moreover, the modem is designed to be energy-efficient, consuming less power than many competing models. This is beneficial for both environmental considerations and cost savings for users over time. The TRENDnet 1206 also comes equipped with diagnostic LEDs, allowing users to easily monitor connection status, data transmission, and power activity.

In conclusion, the TRENDnet v.92 PCI Modem, model 1206, is an excellent choice for individuals who require a dependable and efficient dial-up modem. With its robust features, user-friendly design, and advanced technologies, it effectively meets the needs of users seeking stable internet access in various settings. Whether for personal use or in a small office, the TRENDnet 1206 stands out as a practical and effective solution.