CBFTF10xx-15x
FAULT ISOLATION AND RECOVERY
If the Media Converter fails, isolate and correct the failure by determining the answers to the following questions and then taking the indicated action:
1.Is the power LED on the Media Converter illuminated?
NO
•Is the media converter inserted properly into the chassis?
•Is the power cord properly installed in the chassis and at the external power source and does the external power source provide power?
•Contact Technical Support: US/Canada:
International:
YES
•Proceed to step 2.
2.Is the TLNK (twisted-pair link) LED illuminated?
NO
•Check the copper cables for proper connection and pin assignment.
•Contact Technical Support: US/Canada:
International:
YES
•Proceed to step 3.
3.Is the FLNK (fiber-pair link) LED illuminated?
NO
•Check the fiber cables for proper connection.
•Verify that the TX and RX cables are connected to the RX and TX ports, respectively, on the
•Contact Technical Support: US/Canada:
International:
YES
•Proceed to step 4.
4.Is the TSPD (twisted-pair speed) LED illuminated?
NO
•Check the copper cables for proper connection.
•Off = The Media Converter has selected 10Mb/s operation.
•If the speed is not correct, disconnect and reconnect the twisted pair cable to restart the initialization process.
•Contact Technical Support: US/Canada:
International:
YES
•On = The Media Converter has selected 100Mb/s operation.
•If the speed is not correct, disconnect and reconnect the twisted pair cable to restart the initialization process.
•Contact Technical Support: US/Canada:
International:
CONTACT US
Technical Support
Technical support is avialable 7:00 AM - 6:00 PM CST (GMT
US and Canada:
International: 00-1-952-941-7600
Transition Now
Chat live via the Web with Transition Networks Technical Support. Log onto www.transition.com and click the Transition Now link.
Web-Based Seminars
Transition Networks provides seminars via live
E-Mail
Ask a question anytime by sending an
Address
Transition Networks
6475 City West Parkway, Minneapolis, MN 55344, USA
telephone:
|
|
| DECLARATION OF CONFORMITY |
|
|
| |
|
|
| |
Name of Mfg: | Transition Networks | ||
|
|
| 6475 City West Parkway, Minneapolis MN 55344 USA |
Model: | |||
Part Number(s): | |||
|
|
| |
|
|
| |
Regulation: | EMC Directive 89/336/EEC |
Purpose: To declare that the
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s).
| _August 8, 2002_____ |
Stephen Anderson, | Date |
10 Tech Support: | techsupport@transition.com | 11 |