Transition Networks N-GXX-XX-01 Cable Specifications Technical Specifications, Fiber cable

Page 3

N-GxX-xx-01(x) Gigabit Ethernet NIC

Cable Specifications

Technical Specifications

Fiber cable

Bit error rate:

Single mode fiber (recommended): Multimode fiber (recommended): Multimode fiber (optional):

N-GSX-SC-01(x)

Fiber optic transmitter power: Fiber optic receiver sensitivity: Link budget:

N-GSX-LC-01(x)

Fiber optic transmitter power: Fiber optic receiver sensitivity: Link budget:

N-GLX-SC-01(x)

Fiber optic transmitter power: Fiber optic receiver sensitivity: Link budget:

N-GLX-LC-01(x)

Fiber optic transmitter power: Fiber optic receiver sensitivity: Link budget:

<10-9

9µm 62.5/125 µm

100/140, 85/140, 50/125 µm

850 nm multimode

 

min: -9.5 dBm

max: -4.0 dBm

min: -18.0 dBm

max: -0.0 dBm

8.5 dB

 

850 nm multimode

 

min: -9.5 dBm

max: -4.0 dBm

min: -18.0 dBm

max: -0.0 dBm

8.5 dB

 

1310 nm single mode

min: -9.5 dBm

max: -3.0 dBm

min: -20.0 dBm

max: -3.0 dBm

10.5 dB

 

1310 nm single mode

min: -9.5 dBm

max: -3.0 dBm

min: -20.0 dBm

max: -3.0 dBm

10.5 dB

 

For models N-GxX-xx-01 and N-GxX-xx-01(L)

Standards:

IEEE 802.3™, 802.1P, 802.1Q

Expansion bus standard:

PCI 2.2 64/32 bit, 33/66Mhz standard

Data rate

1000Mbps fiber media

LED:

LINK/ACT (on the bracket):

 

• ON = communication link;

 

• FLASHING = activity on link

 

FDX (on the bracket): ON = full duplex link

Drivers:

• NetWare Server 4.x, 5.x; 6.x

 

• Netware DOS Client ODI

 

• Windows 98, 2000, 2003, NT4.0, XP

 

• Linux

 

• SCO UnixWare 7.1x

 

• OpenUnix 8.0

Boot server support:

PXE Boot ROM

PCB dimensions:

2.2” x 6.5” x .09”

 

(56 mm x 165 mm x 23 mm)

Shipping weight:

1 lb. (0.45 kg.)

Power consumption:

2.0A @ +5VDC

MTBF

127,234 hours (Bellcore7 V5.0)

The fiber optic transmitters on the device meet Class I Laser safety requirements per IEC-825/CDRH standard and comply with 21CRF1040.10 and 21CRF1040.11.

Opearting temp:

0°C to 50°C (32°F to 122°F)

Storage temp:

-25°C to 85°C (-13°C to 185°F)

Humidity:

5% to 95%, non-condensing

Altitude:

0 to 10,000 feet

Warranty:

Lifetime

WARNING: Visible and invisible laser radiation when open: DO NOT stare into the beam or view directly with optical instruments. Failure to observe this warning could result in damage to your vision or blindness.

WARNING: Use of controls, adjustments, or the performance of procedures other than those specified herein may result in hazardous radiation exposure.

The information in this manual is subject to change without further notice. Go to www.transition.com/TransitionNetworks/Products2/Static/MediaConversion.aspx to check for updates to this manual by checking the revision level.

4

Tech Support: 1-800-260-1312 International: 00-1-952-941-7600, 24 hours

 

techsupport@transition.com -- Click the “Transition Now” link for live Web chat.

5

Image 3
Contents GxX-xx-01 standard GxX-xx-01L low profile USER’S GuideInstallation and Configuration Fiber cable Cable Specifications Technical SpecificationsContact Us TroubleshootingDiagnostics LEDs and Boot ROM Boot ROMFCC regulations Canadian regulations Compliance Information