Using the Coaxial Transceiver
The TRANSITION Networks Ethernet™ Coaxial Transceiver can be attached to a PC or hub, using an IEEE 802.3 AUI drop cable.
SQE ON: Set the SQE jumper to ON when the Transceiver is connected to a terminal device.
SQE OFF: Set the SQE jumper to OFF when the Transceiver is connected to a hub or repeater.
T R A N S I nTe It wOo rNk s
Mpls, MN 55344
NETWORK
SQE "ON"
SQE "OFF"
Power
SQE Enabled
Ethernet™
Coaxial
Transceiver
T R A N S I nTe It wOo rNk s
Mpls, MN 55344
Installation Notes
Troubleshooting
TRANSCEIVER
ASSEMBLY
SQE
ON
SQE
OFF
•If connecting the Coaxial Transceiver to a terminal device, set the SQE jumper to ON by installing the SQE jumper as shown. NOTE: The SQE jumper is shipped in the default OFF position.
•If connecting the Coaxial Transceiver to a hub or repeater, leave
AMP TAP
the SQE jumper in the default OFF position as shipped. | ASSEMBLY |
|
•Attach the AMP tap assembly to the transceiver assembly by
removing the two screws (shown) from the transceiver assembly, sliding the AMP tap assembly into the transceiver assembly, and then reinstalling the two screws.
If the Coaxial Transceiver fails, ask the following question:
1.Is the power LED on the Coaxial Transceiver illuminated?
NO
• Verify that AUI cables are IEEE 802.3 |
compliant. |
• Verify that AUI cables are connected to |
PC or hub. |
• Verify that PC or hub connected to AUI |
is powered ON. NOTE: Coaxial |
• Connect the AMP tap assembly to the network:
TRANSCEIVER
Transceiver is powered by PC or hub. |
Model MC02: The transceiver is attached to the thick coax via the AMP tap assembly, part number
ASSEMBLY
• Contact Technical Support at (800) 260- |
1312 or at (800) |
YES
• Proceed to step 2. |
2. Does Coaxial Transceiver provide access to |
Model MC03: The transceiver is connected to thick coax through the attached female N connectors on the AMP tap assembly, part number
Model MC04: The transceiver is connected to the thin coax through the attached BNC T connector on the AMP tap assembly, part number
Model MC05: The transceiver is connected through the attached straight BNC connector on the AMP tap assembly, part
number
•AUI drop cable assembly cannot exceed 50 meters (165 feet).
•When installing thin or thick coax cable, remember to install a 50 ohm terminator at each end of the segment. Be sure that one end of the segment is connected to earth ground.
network? |
NO |
• Verify that coaxial network segment is |
properly terminated at each end with 50 |
ohm terminator. |
• Verify that coaxial network segment is |
properly grounded at one end. |
• Contact Technical Support at (800) 260- |
1312 or at (800) |