WARNING: Do not connect the power supply module to the external power source before installing it into the chassis. Failure to observe this caution could result in equipment damage and/or personal injury or death.
Maintenance
Replace the CPSMP-200
NOTE: The
On/Off Switch
I |
0 |
AC Power Cord
To replace the
1.Ensure the On/Off switch on the power supply module is set to “0”.
2.Disconnect the AC power cord from the AC power source.
3.Remove the two (2) screws that secure the power supply module to the chassis. Retain the screws for installing the replacement module.
4.Carefully slide the power supply module out of the chassis.
I 0
I 0
5.Set the Primary/Secondary switch and the Management/Manual switch on the replacement power supply module, if necessary (see page 3).
I 0
I | Primary/Secondary Switch |
0 | and |
| Management/Manual Switch |
6.Carefully slide the replacement power supply module into the installation slot, aligning the module with the installation guides.
7.Ensure that the power supply module is firmly seated inside the chassis.
8.Carefully install the two (2) retained screws through the power supply module into the chassis, rotating clockwise to secure.
9.See the “Connect to External Power” section (page 5) for instructions on
6 | Tech Support: | techsupport@transition.com | 7 |