Transition Networks CPSMP-200 technical specifications Technical Specification, Replace the Fuse

Page 5

CPSMP-200

Replace the Fuse

CAUTION: Ensure that the power supply module has been disconnected from the external power source and the module’s On/Off switch has been set to “0”. Failure to observe this caution could result in damage to, and subsequent failure of, the power supply module.

NOTE: The CPSMP-200 power supply module may be “hot swapped” (i.e., serviced while the chassis is in operation) provided the module to be serviced has been disconnected from its external power supply and the module’s On/Off switch has been set to “0”.

To replace the fuse in the CPSMP-200 power supply module:

1.Ensure the On/Off switch on the power supply module is set to “0”.

2.Disconnect the AC power cord from the external power source.

3.From the inside edge of the power receptacle, insert a small flat blade screwdriver into the groove on the front, inside edge of the fuse holder and carefully pry the fuse holder from the power supply module.

On/Off Switch

I

0

Fuse Holder

Fuse

4.Carefully remove the fuse from the fuse holder.

5.Install a same size and rating replacement fuse in the fuse holder.

6.Return the fuse holder and fuse to the installation position in the power supply module. Snap the fuse holder into place.

7.See the “Connect to External Power” section (page 5) for instructions on re-connecting the power supply module to the external power source.

Technical Specification

For use with Transition Networks Model CPSMP-200 or equivalent.

Standards

UL Listed EN60950; FCC & CISPR Class A&B;

 

EN61000-3-2 Class D; CE Mark

Dimensions

8.3" x 8.4" x 2.7" (211 mm x 211 mm x 69 mm)

Weight

1 lb. (0.45 kg) approximately

Power Input

100-240 V, 47/63Hz, 0.62-1.5 Amp,

 

(typical with a fully-loaded chassis)

Voltage Tolerance

± 10%

 

Low-Line Input Current

3.3A max.

 

Inrush Current

40A max.( peak starting current) @ high line

Transient Recovery Time 1ms max.

 

Power Output

12VDC at 10.83 Amp max.

 

Power Factor

> 0.95 (no inductive or capacitive distinction)

Fuse

4 Amp/250 V

 

MTBF

60,000 hours (MIL217F2 V5.0) (MIL-HDBK-217F)

 

248,000 hours (Bellcore7 V5.0)

Environment

Tmra*:

0 to 60°C (32 to 140°F )

 

Storage Temperature:

-20 to 85°C (-4 to 185°F)

 

Humidity:

5 to 95%, non condensing

 

Altitude:

0 to 10,000 feet

Warranty

Lifetime

 

*Manufacturer’s rated ambient temperature: Tmra range for this power supply module depends on the physical characteristics and the installation configuration of the Transition Networks PointSystem™ chassis in which this module will be installed.

8

Tech Support: 1-800-260-1312-- International: 00-1-952-941-7600-- (24 hours)

techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.

9

Image 5
Contents User’s Guide PointSystem CPSMC18xx-xxx Accessory CPSMC19xx-100 AccessorySwitch Settings InstallationManagement/Manual Switch Primary/Secondary SwitchSet the On/Off switch on the power supply module to Install the CPSMP-200Connect to External Power Replace the CPSMP-200 MaintenanceDisconnect the AC power cord from the AC power source Replace the Fuse Technical SpecificationContact Us TroubleshootingCopyright Restrictions Compliance InformationTrademark Notice