Transition Networks SISTF10xx-130-LR(T) specifications Internal Relay, Power the SISTF10xx-130-LRT

Page 4

SISTF10xx-130-LR(T)

Installation -- Continued

Switch 6: Ring Master

on: Enables the device to be the Ring Master in a Redundant Ring topology.

This setting also enables the Redundant Ring break alarm. If a link in the Redundant Ring breaks (and if the SISTF10xx-130-LR(T) is the Ring Master in the Redundant Ring topology), then the internal relay forms an open circuit and the FAULT LED lights up.

off: Disables the device from being the Ring Master.

If none of the devices are set to be the Ring Master, the Redundant Ring technology chooses the device that has the smallest MAC address range to be the Ring Master. However, if the Redundant Ring is broken, the internal relay remains closed and the FAULT LED remains off.

Internal Relay

The internal relay that activates the alarm feature is connected to the two middle contacts on the 6-contact terminal block. A user-supplied fault alarm device can be connected to these fault contacts. An example would be to

Installation -- Continued

Power the SISTF10xx-130-LR(T)

This device is suitable for use in Class I, Division 2, Groups A, B, C and D or non-hazardous locations only.

WARNING: EXPLOSION HAZARD - Do not disconnect equipment unless power has been removed or the area is known to be non- hazardous.

WARNING: EXPLOSION HAZARD - Substitution of components may impair suitability for Class I, Division 2.

The SISTF10xx-130-LR(T) is designed for both a primary and a backup power supply via the 6-contact terminal block, located on the top panel of the device. Both power inputs can be connected simultaneously to live DC power sources. If one power source fails, the other live source acts as a backup, and automatically supplies the device with power.

6-contact terminal block

connect the fault circuit to a warning light located in the control room. The light can be set up to turn on when a fault is detected (see below).

Install the Port Alarm Device

A user-supplied port alarm device can be connected to the SISTF10xx-130-LR to alert the user whenever a power fault or a port fault occurs. At least one port alarm switch or the Ring Master switch (see page 5) must be “ON” to enable the port alarm feature.

backup power

 

V2+

 

 

contacts

 

V2-

 

 

 

 

 

 

primary power

 

V1+

contacts

 

 

 

 

V1-

 

 

PWR2

FAULT

PWR1

V1, V2 INPUTS

12-48 VDC

The screws to secure the wire are located on the side of the terminal block.

 

V2+

fault contacts

V2-

 

 

 

 

V1+

 

V1-

PWR2

FAULT

PWR1

The screws to secure the wires are located on the side of the terminal block.

CAUTION: Before connecting the SISTF10xx-130-LR(T) to the 12-48 VDC power source, ensure the power source voltage is stable.

To provide PRIMARY (PWR1) power to the SISTF10xx-130-LR(T):

1.Insert the positive (+) DC wire from the 12-48VDC power source into the terminal marked “V1+”.

2.Insert the negative (-) DC wire into the terminal marked “V1-”.

3.Secure the wires by tightening the corresponding screws on the side of the terminal block.

The contacts for the fault alarm are on the 6-contact terminal block, located on the top panel of the SISTF10xx-130-LR(T). To install a port alarm device:

1.Insert the two wires from the user-supplied port alarm device into the two terminals marked “FAULT” on the 6-contact terminal block.

2.Secure the wire by tightening the corresponding screw on the side of the terminal block.

To provide BACKUP (PWR2) power to the SISTF10xx-130-LR(T):

1.Insert the positive (+) DC wire from the 12-48VDC power source into the terminal marked “V2+”.

2.Insert the negative (-) DC wire into the terminal marked “V2-”.

3.Secure the wires by tightening the corresponding screws on the side of the terminal block.

6

24-hour Technical Support: 1-800-260-1312-- International: 00-1-952-941-7600

techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.

7

Image 4
Contents User’s Guide Part NumberInstallation DIN-Rail MountGround the SISTF10xx-130-LRT Master DeviceInstall the Fiber Cable Install the Copper CableSet the Dip Switches Switches 1 5 Port AlarmInstall the Port Alarm Device Power the SISTF10xx-130-LRTInternal Relay Features On = Primary power is connected to deviceOperation Status LEDsCopper Cable Cable SpecificationsFiber Cable Warranty Technical SpecificationsProcessing Type Store and Forward Troubleshooting Compliance Information European RegulationsContact Transition Networks Trademark Notice