C
System configurator and
PRIMERGY R450 | Status |
Section VII
SCSI-/Fibre-channel controller
A.
The following cabling is standard, if no Disk Array Controller is used
1.Channel A of the U160 controller is connected to the 1st backplane for 3 HDs
2.Channel B of the U160 controller is connected to the 2nd backplane for 3 HDs
|
|
|
|
|
|
|
|
|
|
|
|
| This interface is only configurable if a RAID Controller | |
| External |
| besides the | |
| Cable and external |
| See section Disk Array Controlller | |
| connector interface |
|
| |
| max. 2x per system for external |
|
| |
|
|
|
|
|
B. SCSI - controller for external hard disk extensions and external peripheral devices.
4x
5x
while stocks last
SNP:SY-F1722E1-P
SCSI Controller UW, DE
Adaptec 2944UW (HBA)
1 channel
32/33 PCI, min. 170mm
int: LD50 + HD68, ext: HD68(S)
SW:
max. 2x per system
S26361-F2399-E1
SCSI U160 Controller
Adaptec SCSI card 29160
1 channel: LVD+Fast/Ultra (decoup.) LVD con. for HD, withoud cable Fast/Ultra con. access. drives
64/66 (32/33) PCI, min. 180mm
int: Fast
+LVD HD68; ext: HD68(LVD) SW:
max. 2x per system
Controller for the connection of a EMC Symmetrix (only available as option)
Supported only in Microsoft Windows NT and Windows 2000 operating systems
C. Fibre Channel controller for subsystems and SAN
4x
| while | stocks last |
| while | stocks last |
| |||||
|
|
|
|
|
|
| |||||
| 1GBit/s FC Controller |
|
| 1GBit/s FC Controller |
|
| |||||
| Qlogic |
|
| Qlogic |
|
|
| ||||
| QLA 2200 |
|
| QLA 2200F, full height braket |
|
| |||||
| 1 Channel 1GBit/sec FC Controller |
|
| 1 Channel 1GBit/sec FC Controller |
|
| |||||
| CU (copper) Interface |
|
| MMF(Multimode Fibre) Interface |
|
| |||||
| incl. SW and description (Ger/US) |
|
| incl. SW and description (Ger/US) |
|
| |||||
| PCI 64Bit / 66MHz, 175mm |
|
| PCI 64Bit / 66MHz, 175mm |
|
| |||||
| 3.3V and 5V tolerant signaling |
|
| 3.3V and 5V tolerant signaling |
|
| |||||
| max. 4x per system |
|
| max. 4x per system |
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| while | stocks last | |
|
|
|
|
|
|
|
| ||||
|
|
| 2GBit/s FC Controller |
|
| 2GBit/s FC Controller | |||||
|
|
| Emulex |
|
|
| Emulex | ||||
|
|
| LP9802 |
|
|
| LP9002L | ||||
|
|
| 1 Cannel 2GBit/sec FC Controller |
|
| 1 Channel 2GBit/sec FC Controller | |||||
|
|
| LC Interface for 50um Fiber |
|
| LC Interface for 50um Fibre | |||||
|
|
| PCI 64Bit / 133MHz, 170mm |
|
| PCI 64Bit / 66MHz, 170mm | |||||
|
|
| 3.3V and 5V tolerant signaling |
|
| 3.3V and 5V tolerant signaling | |||||
|
|
| max. 4x per system |
|
|
| max. 4x per system | ||||
|
|
|
|
|
|
|
|
|
|
|
|
suitable for 64Bit/66MHz
Attention
2GBit/s FC Controller require other interface connectors for the optical cables than 1GBit/s fibre channel.
SNP:SY-F1826L1-P
FC Ctrl for EMC2 Attachment
Emulex LP8000
1 channel 100MB/s
MMF (Multimode Fibre) Interface Connector: Duplex SC
without cable, order seperately
incl. SW a. description (Ger/US)
PCI 64Bit/33MHz controller
max. 4x per system
Supported only in Microsoft Windows NT and Windows 2000 operating systems.
Controller for the connection
of a EMC Symmetrix, FibreCAT (only available as option)
There are other components such as switches, GBICs or cables which can be ordered for fibre channel SAN attachments. (see price list)
to be continued on next page
All controllers for the connection of external storage systems are delivered without cables For the configuration of external cabling see the configurator for external storage systems
D
Fujitsu Siemens Computers | 8 of 12 |
Enterprise Products - PRIMERGY Server |