Fujitsu TX150 S4 Scsi controller for internal backup drives S26361-F2399-E2, Section, Disk Array

Page 13

 

 

 

 

 

 

 

System configurator and order-information guide

 

G

 

 

 

 

PRIMERGY TX150 S4

Status 25.11.2005

 

 

 

B. SCSI controller for internal backup drives

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S26361-F2399-E2

 

 

 

 

 

 

SCSI 160 Controller

 

 

 

 

 

 

Adaptec SCSI Card 29160

 

 

 

 

 

 

1 channel: LVD + Fast/ Ultra (decoupl.)

 

 

 

 

 

LVD connect. for HD, without cable

 

 

 

 

 

Fast/Ultra connect. for acc. drives

 

 

 

 

 

 

64/66 PCI, min 180 mm

 

 

 

 

 

 

int: Fast 50-pin or Ultra HD68

 

+LVD HD68; ext: HD68(LVD) SW:

max. 1x per system

S26361-F2814-E6

68-Pin Kit for accessible drives

Cable with Terminator To connect acc. drives to separate SCSI controller

max. 1x per system

C. SCSI controller for external drives and peripheral devices

S26361-F2399-E1

SCSI U160 controller

Adaptec SCSI Card 29160

1 channel: LVD + Fast/ Ultra (decoupl.) LVD connect. for HD, without cable Fast/Ultra connect. for acc. drives

64/66 PCI, min 180 mm

int: Fast 50 pol oder Ultra HD68

+LVD HD68; ext: HD68(LVD) SW:

max. 1x per system

Only SX10 Backup is for external connection at the SCSI controller.

Section

max. 4x

to be

continued on next page

VIII

Disk Array

D.LSI - Controller

1-channel Ultra 320 SCSI on-board controller with LSI Integrated Mirroring (IME) Standard SCSI-cabling of a PRIMERGY TX150 S4 basic unit with on-board controller Ultra 320 SCSI controller is connected to the internal hard disks and internal backup devices, if no additional HD/backup device controllers are configured.

1x per PRIMERGY TX150 S4

D.zero-channel RAID controller (320-0x) for internal Disk Array

and additional RAID controllers for internal / external Disk Array S26361-F3085-E128

 

0-channel RAID controller

 

 

 

LSI

 

 

 

320-0x

 

 

 

128MB SDRAM ECC Cache

 

 

 

BBU optional

 

Zero channel RAID controller

 

in combination with on-board

 

LSI must be installed in the

 

U320 SCSI controller

 

blue marked bay.

 

without cable

 

 

 

64Bit/133MHz PCI-X controller

 

With zero channel RAID controller

 

3.3V power supply & signaling

 

the IME function is no longer

 

max. 1x per system

 

available.

 

 

 

 

 

 

 

 

 

 

 

S26361-F3085-E10

 

 

 

Cache Battery Backup Unit

 

 

 

max. 1x pro Controller

 

 

 

 

 

 

 

H

Fujitsu Siemens Computers

13 of 18

Enterprise Products - PRIMERGY Server

Image 13
Contents Primergy TX150 S4 S26361-XXX-XXX SectionIII Memory, exampleConfiguration diagram Primergy TX150 S4 SW Configurator IA32 Microsoft Software W SW Configurator EM64TOnly Only EM64T Linux Software LSection Basic unit Cables included in basic unitS26113-F483-E11 S26113-F483-E1Floorstand versions For later mounting in racks the following kits are available Refer configurator PC-rack max x per SystemSection Processor Memory Dual channel memory configurations for maximum performanceS26361-F3000-E513 S26361-F3000-E514 S26361-F3000-E515 Section GraphicsSection Accessible drives Section Hard Disk Drives S26361-F2814-E6S26361-F3121-E173 S26361-F3121-E114 S26361-F3121-E130 Ultra 320 Scsi 320MB/sT26139-Y3849-L1 Section SCSI-ControllerSection Scsi controller for internal backup drives S26361-F2399-E2Disk Array S26361-F3085-E10On previous S26361-F3053-E1 Section Communication / NetworkS26361-F3142-E1 S26361-F3011-E1Section System management options S26361-F2425-E305 RSB S2 LP external power supplyS26361-F2425-E103 Section MiscellaneousSection Country specific / rack specific options Cange Report