Fujitsu MAX3147FC, MAX3073FC, MAX3036FC manual Contents

Page 17

CONTENTS

CHAPTER 1

General Description

1-1

 

1.1

 

Standard Features

1-2

 

1.2

 

Hardware Structure

1-5

 

1.3

 

System Configuration

1-7

CHAPTER 2

Specifications

2-1

 

2.1

 

Hardware Specifications

2-1

 

2.1.1

Model name and order number

2-1

 

2.1.2

Function specifications

2-2

 

2.1.3

Environmental specifications

2-4

 

2.1.4

Error rate

2-5

 

2.1.5

Reliability

2-5

CHAPTER 3

Data Format

3-1

 

3.1

 

Data Space

3-1

 

3.1.1

Cylinder configuration

3-1

 

3.1.2

Alternate spare area

3-4

 

3.1.3

Track format

3-5

 

3.1.4

Sector format

3-6

 

3.1.5

Format capacity

3-8

 

3.2

Logical Data Block Addressing

3-8

 

3.3

 

Defect Management

3-10

 

3.3.1

Defect list

3-10

 

3.3.2

Alternate block allocation

3-10

CHAPTER 4

Installation Requirements

4-1

 

4.1

 

Mounting Requirements

4-1

 

4.1.1

External dimensions

4-1

C141-E234

xi

Image 17
Contents C141-E234-01EN For Safe Operation C141-E234 This page is intentionally left blank Revision Record Fibre Channel Physical and Signaling INTERFACE-2 FC-PH-2 Fibre Channel Physical and Signaling Interface FC-PHFibre Channel Arbitrated Loop FC-AL Fibre Channel Protocol for Scsi SCSI-FCPOverview of Manual PrefaceConventions for Alert Messages PrefaceC141-E234 Iii This page is intentionally left blank Important Alert Messages Important Alert ItemsImportant Alert Items C141-E234 Vii This page is intentionally left blank Specifications Maintenance ManualManual Organization Product Fibre ChannelThis page is intentionally left blank Contents Contents InstallationAppendix a Figures Tables This page is intentionally left blank Standard Features Standard Features Hardware Structure System ConfigurationGeneral Description Standard Features General Description FC model drives outer view Hardware StructureGeneral Description Example of FC-AL system configuration System ConfigurationThis page is intentionally left blank Model names and order numbers Hardware SpecificationsHardware Specifications Model name and order number Function specifications SpecificationsHardware Specifications Environmental/power requirements Environmental specificationsReliability Error rateMtbf = Hardware Specifications This page is intentionally left blank Data Space Cylinder configurationData Space Logical Data Block Addressing Defect Management SA0 Data FormatData Space Spare area in cell Alternate spare areaTrack format Sector format Track skew/head skewData Space Format capacity Logical Data Block Addressing Alternate block allocation Defect Management Defect listDefect Management Alternate block allocation by Format Unit commandAlternate block allocation by Reassign Blocks command Write Write Extend Write Write Extended Format Unit Mounting Requirements External dimensions Installation RequirementsDimensions Installation RequirementsMounting orientations Mounting RequirementsMounting frame structure Limitation of side-mounting MPU Surface temperature check pointHDC Service clearance area MAX3147FC MAX3073FC MAX3036FC Connection Requirements Connector location10 SCA2 type connector Interface connectorInstallation Installation Setting Loop ID setting SettingMode settings Motor start modeMounting Drives Mounting procedures C141-E234 Checking connection Checking the HDD connection a Checking the HDD connection B Formatting Installation Setting parameters Arre AwreArre Awre PER Xxxx DiscXffff Port Discovery Dismounting Drives Self-diagnostic functions Diagnostics Self-diagnosticsDiagnostics and Maintenance Diagnostics Test programs Maintenance Information Precautions Maintenance InformationMaintenance requirements Maintenance levels Revision label example Revision numbersTests Tools and test equipmentTest flowchart Operation Check Diagnostic testOperation Check Initial seek operation check Operation testTroubleshooting with disk drive replacement in the field System-level field troubleshooting Troubleshooting ProceduresDisk drive troubleshooting Troubleshooting at the repair siteFinding possibly faulty parts Troubleshooting ProceduresTroubleshooting with parts replacement in the factory This page is intentionally left blank Error Analysis Information Collection Sense data Error Analysis Information Collection Sense Data AnalysisILI Error AnalysisLSB SksvDefinition of sense data Sense Data AnalysisSense data 3-0C-03, 4-40-xx, and 4-C4-xx Sense data 1-1x-xx, 3-1x-xx and E-1D-00 Disk read errorInterface FC-SCA Connector Signal Allocation Appendix a Connector Signal AllocationConnector Signal Allocation Glossary Target Targ GlossaryAcronyms and Abbreviations OEM Acronyms and AbbreviationsECC BcrcIndex Mode SELECT/MODE SelectMtbf Mttr PADC141-E234 IN-3 This page is intentionally left blank Comment Form This page is intentionally left blank
Related manuals
Manual 1 pages 10.6 Kb

MAX3147FC, MAX3036FC, MAX3073FC specifications

The Fujitsu MAX3036FC, MAX3073FC, and MAX3147FC are advanced integrated circuits that cater to a variety of high-performance applications, predominantly in the realm of communications and data transmission. Each model comes laden with unique features that help in addressing specific requirements in modern electronic systems.

The MAX3036FC, for instance, stands out due to its robust signal processing capabilities. It is particularly optimized for high-speed data communications, making it an excellent choice for applications that demand minimal latency and high data integrity. This featured IC operates within a wide voltage range, ensuring versatility in different circuit environments. It also adopts technology enabling low power consumption, an essential attribute in battery-operated devices.

In contrast, the MAX3073FC brings a distinct set of features suitable for more specialized applications. Its architecture supports a comprehensive serial data communication framework, making it ideal for designs that utilize various communication protocols, including those in industrial automation and automotive systems. The MAX3073FC supports advanced error correction mechanisms which enhance reliability, ensuring more accurate data transmission even over longer distances.

The MAX3147FC, on the other hand, focuses on integrating advanced timing and synchronization technologies. This model is particularly significant in applications that require precise timing signals, such as in telecommunications infrastructure and high-frequency trading systems. The MAX3147FC features integrated oscillators and buffers, streamlining the design process and reducing component count. Additionally, it boasts immunity to electromagnetic interference, a critical factor in maintaining signal integrity in noisy environments.

Common to all three models is Fujitsu's commitment to use cutting-edge manufacturing processes. This ensures the devices are compact, enhancing their suitability for modern designs where space is constrained. The ICs are also designed to handle varying temperature ranges, making them resilient for use in diverse environments.

Each IC is supported by comprehensive documentation and development tools that aid engineers in the rapid prototyping and deployment of their designs. The integration of these advanced features and technologies not only simplifies the design process but also accelerates time-to-market for new products. Whether addressing the demands of communication systems, industrial controls, or consumer electronics, the MAX3036FC, MAX3073FC, and MAX3147FC from Fujitsu represent exceptional flexibility and performance in the landscape of integrated circuit technology.