Fujitsu MHV2160BT manual Troubleshooting Procedure, Troubleshooting procedure

Page 28

Maintenance and Diagnosis

1.3Troubleshooting Procedure

1.3.1 Troubleshooting procedure

This section describes the troubleshooting procedures for a disk drive failure at field maintenance level described in Subsection 1.1.3.

In this section, troubleshooting is made to isolate the reported failure to the disk drive or a host system. Usually, troubleshooting is necessary only when a cause of failure is uncertain or unknown. When a cause of failure is clear (for example, abnormal sound in the DE or burnt parts on the PCA), a level of troubleshooting is low.

1.3.2 Troubleshooting disk drive replaced in field

It is recommended that the whole drive be replaced in maintenance of this level. If replacing the drive corrects the fault, return the old drive to the factory for testing and repair. If the new drive shows the same fault as the one that was removed, the failure is elsewhere in the system.

System level troubleshooting, shown in Table 1.3, is performed at the user site to isolate the reported failure to the disk drive or system.

1-12

C141-F076

Image 28
Contents MHV2160BT Disk Drive Maintenance Manual For Safe Operation Handling of This ManualRevision History This page is intentionally left blank Overview of Manual PrefaceConventions for Alert Messages Operating Environment Hot PlugLiability Exception This page is intentionally left blank Important Alert Messages Important Alert ItemsStatic, Damage Device damage Data corruptionDamage or Device damage This page is intentionally left blank MHV2160BT Disk Drive Maintenance Manual Manual OrganizationThis page is intentionally left blank Contents Illustrations TablesMaintenance and Diagnosis Maintenance Rules for maintenanceMaintenance requirements Data corruption Maintenance levels Refer to .2 of the MHV2160BT Disk Drive Product ManualDisk drive revision number Disk drive revision number labelDisplay of disk drive revision number Tools and test equipment Self-diagnosticsTest Test flowchart Status Field contents Disposition for Error Field contentsOperation Confirmation Diagnostic testOperation test Troubleshooting procedure Troubleshooting ProcedureTroubleshooting disk drive replaced in field System level and field troubleshooting ManualTroubleshooting at factory Removal and Replacement Procedure Disk Drive Removal Spare PartsModel and parts numbers Acronyms and Abbreviations CSSAcronyms and Abbreviations Index Index READER’S Comment Form This page is intentionally left blank C141-F076-01EN This page is intentionally left blank