Fujitsu MHV2080BS, MHV2060BS, MHV2040BS Operation Confirmation, Operation test, Diagnostic test

Page 27

1.2 Operation Confirmation

1.2Operation Confirmation

1.2.1 Operation test

When the host computer is processing data, the disk drive monitors disk drive operation errors including data, command, and seek errors. The host is notified of the error that the disk drive detected and the user is notified of its result.

The user may notice intermittent and indefinite failures such as overlong execution time, abnormal noise, abnormal odor, or failures in particular processes.

The failure reported in the operation test will need further investigation. To ascertain the cause of the disk drive failure reported, the disk drive can be replaced. Failures in the operation test are often not caused by the host system. For example, not having enough power supply reserve, a loose cable connection, no timing and mechanical reserves, or relationship with other systems.

In normal operation, the disk drive itself or the host determines the processing (return or halt) following the detected failure state.

To troubleshoot the failure reported in the test at this level, accurately reproduce the condition that caused the failure. Then, by replacing the disk drive, try to separate the fault from the other sections of the disk drive host system.

1.2.2 Diagnostic test

The diagnostic test is used to separate a confirmed disk drive failure to a disk drive subassembly or to check the disk drive performance. A test of this level usually includes a specific disk drive function or concentrated execution of a group of functions. The test is usually performed by a factory engineer and not where the failure was reported. The disk drive is tested using another host computer or test equipment.

To troubleshoot the disk drive failure in the diagnostic test, the engineer will reproduce the failure condition. The engineer then isolates the failure to a subassembly or part of the disk drive.

The procedures used in a test of this level great depend on the test equipment used. It is beyond the range of this manual.

C141-F075

1-11

Image 27
Contents MHV2080BS, MHV2060BS, MHV2040BS Disk Drives Maintenance ManualHandling of This Manual For Safe OperationRevision History This page is intentionally left blank Preface Overview of ManualConventions for Alert Messages Hot Plug Operating EnvironmentLiability Exception This page is intentionally left blank Important Alert Items Important Alert MessagesStatic, Damage Data corruption Device damageDamage or Device damage This page is intentionally left blank Manual Organization MHV2040BS Disk Drives Maintenance ManualThis page is intentionally left blank Contents Tables IllustrationsMaintenance and Diagnosis Rules for maintenance MaintenanceMaintenance requirements Data corruption Storage Store in dampproof packaging Maintenance levelsDisk drive revision number label Disk drive revision numberDisplay of disk drive revision number Self-diagnostics Tools and test equipmentTest Test flowchart Disposition for Error Field contents Status Field contentsDiagnostic test Operation ConfirmationOperation test Troubleshooting Procedure Troubleshooting procedureTroubleshooting disk drive replaced in field MHV2040BS Disk Drives Product Manual System level and field troubleshootingTroubleshooting at factory Removal and Replacement Procedure Spare Parts Disk Drive RemovalModel and parts numbers CSS Acronyms and AbbreviationsAcronyms and Abbreviations Index Index READER’S Comment Form This page is intentionally left blank C141-F075-01EN This page is intentionally left blank

MHV2040BS, MHV2060BS, MHV2080BS specifications

Fujitsu's MHV series of hard disk drives, including the MHV2040BS, MHV2060BS, and MHV2080BS, are designed for high-performance applications in various computing environments. These models feature a 2.5-inch form factor, making them suitable for both laptop and desktop systems, where space and efficiency are crucial.

The MHV2040BS, with a capacity of 40GB, provides an ideal solution for users requiring dependable storage for basic computing tasks. The MHV2060BS boosts the capacity to 60GB, accommodating users who require additional space for multimedia files and applications. For those needing significant storage, the MHV2080BS comes in at 80GB, catering to heavier workloads and larger datasets.

All three models utilize a robust 5400 RPM spindle speed, offering a balance between performance and energy efficiency. The drives are equipped with an Ultra ATA/100 interface, enabling high data transfer rates for smoother operation and faster file access. This interface is particularly beneficial for users operating in environments with demanding I/O operations.

In terms of technologies, the MHV series integrates advanced features aimed at enhancing data integrity and performance. The drives utilize Fluid Dynamic Bearings (FDB) that minimize mechanical noise and vibration, resulting in quieter operation and increased reliability over time. Additionally, these models are designed to withstand higher shock levels, making them resilient in mobile applications or environments where durability is paramount.

The MHV series is optimized for lower power consumption, ensuring that users can enjoy longer battery life in portable devices while maintaining system performance. With a mean time between failures (MTBF) rating that exceeds 600,000 hours, Fujitsu emphasizes the longevity and reliability of the MHV2040BS, MHV2060BS, and MHV2080BS drives.

Ultimately, the Fujitsu MHV series represents a blend of innovation and practicality. With their robust build quality, commendable performance characteristics, and energy-saving features, they cater to a wide range of storage needs, from everyday computing to more demanding applications, making them a suitable choice for both personal and business environments.