IBM DS8000 manual View of the General host information panel

Page 239

Figure 10-31 View of the General host information panel

Click Next to advance to the Define host ports panel shown in Figure 10-32.

Figure 10-32 View of Define host port panel

Enter the appropriate information on the Define host ports panel shown in Figure 10-32.

Note: Selecting “Group ports to share a common set of volumes” will group the host ports together into one attachment. Each host port will require a WWPN to be entered; now, if you are using the Real-time Manager; or later, if you are using the Simulated Manager.

Chapter 10. The DS Storage Manager - logical configuration 217

Image 239
Contents IBM TotalStorage DS8000 Series Page IBM TotalStorage DS8000 Series Concepts and Architecture First Edition April Contents Page Benefits of virtualization Vi DS8000 Series Concepts and Architecture Summary Viii DS8000 Series Concepts and Architecture Page Page Index Xii DS8000 Series Concepts and Architecture Copyright License Dfsort TrademarksTeam that wrote this redbook PrefaceXvi DS8000 Series Concepts and Architecture Preface Xviii DS8000 Series Concepts and Architecture Comments welcome Become a published authorXx DS8000 Series Concepts and Architecture Part 1 Introduction DS8000 Series Concepts and Architecture Introduction to the DS8000 series Business Continuity DS8000, a member of the TotalStorage DS familyOverview of the DS8000 series Infrastructure SimplificationDS8000 Base frame Hardware overview IBM Standby Capacity on Demand offering for the DS8000 Storage capacityStorage system logical partitions LPARs Storage Hardware Management Console S-HMC for the DS8000Resiliency Family for Business Continuity Supported environmentsIBM TotalStorage Metro Mirror Synchronous Pprc IBM TotalStorage FlashCopyIBM TotalStorage Global Mirror Asynchronous Pprc Service and setupThree-site solution InteroperabilityDS8000 compared to ESS PositioningCommon set of functions IBM TotalStorage DS Storage Manager IBM TotalStorage DS Command-Line Interface DS CLICommon management functions DS8000 compared to DS6000DS Open application programming interface Scalability and configuration flexibilityFuture directions of storage system LPARs Performance for zSeries Sequential Prefetching in Adaptive Replacement Cache SarcPerformance IBM TotalStorage Multipath Subsystem Device Driver SDDSummary 16 DS8000 Series Concepts and Architecture Part 2 Architecture 18 DS8000 Series Concepts and Architecture Components Base frame FramesRack operator panel Expansion frameRack operator panel ArchitectureSAN fabric Cache management Server-based SMP designComponents Randomseq Processor complexComponents Processor memory Service processor and SpcnFront view Rear view2 I/O enclosures RIO-GDevice adapters Disk subsystemRear view DS8000 device adapter Disk enclosuresDS8000 disk enclosure Non-switched FC-AL drawbacks11 DS8000 disk enclosure Switched FC-AL advantages12 Disk enclosure switched connections DS8000 switched FC-AL implementationArrays and spares ExpansionArrays across loops 14 DS8000 switched loop layoutDDMs Host adaptersAAL benefits Remote Mirror and Copy with Escon Ficon and Fibre Channel protocol host adaptersControl units and logical paths Escon distancesFibre Channel distances Power and coolingRack Power Control cards RPC Fibre Channel supported serversBattery backup assemblies Primary power suppliesProcessor and I/O enclosure power supplies Disk enclosure power and coolingEthernet switches 42 DS8000 Series Concepts and Architecture Storage system LPARs Logical partitions Partitions Introduction to logical partitioningVirtualization Engine technology Partitioning conceptsLogical partitioning Lpar Building blockPhysical partitioning Ppar Virtual I/O Software and hardware fault isolationDynamic logical partitioning Micro-PartitioningApplication isolation Why Logically Partition?Server consolidation Production and test environmentsIncreased flexibility of resource allocation DS8000 and LparLpar and storage facility images DS8300 Model 9A2 Lpar and storage facility image 2 DS8300 Lpar implementationDS8300 Lpar resource allocation Storage facility image hardware componentsProcessor and memory allocations Storage Facility Image Processor complexRIO-G interconnect separation 4 DS8300 Model 9A2 configuration optionsModel conversion DS8300 example configurationModel conversions regarding Lpar functionality Lpar security through Power Hypervisor PhypLpar protection Power Hypervisor Lpar and Copy ServicesRemote mirroring Lpar benefitsFlashCopy Storage system LPARs Logical partitions Example of storage facility images in the DS8300 Addressing capabilities with storage facility imagesDS8300 addressing capabilities 60 DS8000 Series Concepts and Architecture RAS Storage facility image NamingStorage complex Storage unitProcessor complex Processor complex RASPermanent monitoring Reliability, availability, and serviceability+1 redundancy Memory reliability, fault tolerance, and integritySelf-healing Resource deallocation Fault maskingConcurrent Maintenance Hypervisor Storage image independenceMetadata checks Server RASRIO-G a self-healing interconnect 2 I/O enclosureData flow Server failover and failbackNormal data flow FailoverFailback NVS recovery after complete power lossSingle or multiple path Host connection availabilityEnclosure Multi-pathing software SAN/FICON/ESCON switchesZSeries host connection Open systems host connectionDisk path redundancy Switched disk connectionsRAID-5 implementation in the DS8000 RAID-5 overviewRAID-10 overview RAID-5 theoryRAID-10 implementation in the DS8000 Spare creationRAID-10 theory Hot plugable DDMs Predictive Failure Analysis PFAFloating spares Rack cooling fans Battery backup unitsRack power control card RPC Disk scrubbingEmergency power off EPO Building power lossPower fluctuation protection Power control of the DS8000Installation process Microcode updatesDifferent code versions across storage images Management consoleHMC considerations Virtualization concepts Storage system virtualization Virtualization definitionStorage Facility virtualization Abstraction layers for disk virtualizationPhysical layer as the base for virtualization Array sitesArray site ArraysCreation of an array RanksForming an FB rank with 1 GB extents Extent poolsServer0 Fixed Block LUNs Logical volumesCKD volumes Volume with ISeries LUNs Allocation and deletion of LUNs/CKD volumesLogical subsystems LSS DB2 Address groups Volume accessHost attachment Volume groupSummary of the virtualization hierarchy 11 Host attachments and volume groups12 Virtualization hierarchy Placement of dataBenefits of virtualization 13 Optimal placement of data101 102 DS8000 Series Concepts and Architecture 103 IBM TotalStorage DS8000 model overview and scalabilityModel naming conventions DS8000 highlights2 DS8100 Model 3 DS8300 Models 922 and 9A2 Maximum configuration for the ModelIBM TotalStorage DS8000 model overview and scalability Model comparison DS8000 model comparison Designed for scalabilityScalability for capacity Large and scalable capacityComparison of models for capacity Scalability for performanceAdding DDMs Future planLinear-scalable architecture Way I/O controllersBenefit of the DS8000 for scalability RIO-GModel conversions Model upgrades114 DS8000 Series Concepts and Architecture 115 Copy ServicesPoint-in-Time Copy FlashCopy Introduction to Copy ServicesCopy Services functions Write to the source volume Read from the source volumeRead from the target volume No background copy option Point-in-Time Copy function authorizationRefresh target volume also known as Incremental FlashCopy FlashCopy optionsIncremental FlashCopy Data Set FlashCopyData Set FlashCopy Multiple Relationship FlashCopyConsistency Group FlashCopy What is Consistency Group FlashCopy?FlashCopy Source Volume FlashCopy Target Volume FlashCopy to Pprc Primary VolumeMetro Mirror Synchronous Pprc Inband Commands over Remote Mirror linkRemote Mirror and Copy Peer-to-Peer Remote Copy Persistent FlashCopyMetro Mirror Global Copy PPRC-XDGlobal Copy Global Mirror Asynchronous PprcGlobal Mirror How Global Mirror worksGlobal Mirror How it works OS Global Mirror XRC 11 z/OS Global Mirror Secondary server12 z/OS Metro/Global Mirror Comparison of the Remote Mirror and Copy functionsGlobal Copy PPRC-XD What is data consistency? What is a Consistency Group?How does Consistency Group keep data consistency? 1st LSS13 Storage Hardware Management Console S-HMC Interfaces for Copy ServicesDS Storage Manager Web-based interface 16 DS8000 Copy Services network componentsDS Open application programming Interface API DS Command-Line Interface DS CLITip What is changed from the ESS CLI? Future Plans Interoperability with ESS140 DS8000 Series Concepts and Architecture 141 Part 3 Planning and configuration142 DS8000 Series Concepts and Architecture 143 Installation planningDelivery requirements Packaged dimensions and weight for DS8000 modelsGeneral considerations 145 Installation site preparationFloor and space requirements Calculating space requirements Installing on raised or nonraised floorsMeeting floor load requirements 147 Power requirementsPower control DS8000 dimensionsInput voltage requirements Power outlet requirementsFans and air intake areas Power connector requirementsPower consumption and environmental information Environmental requirementsCooling the storage complex Host attachmentAttaching to open systems hosts 151 ESCON-attached S/390 and zSeries hostsFICON-attached S/390 and zSeries hosts SAN Fabric products Where to get the updated information for host attachmentHost systems attachment 153 Network and SAN requirementsHMC network requirements Channel extension technology productsSAN requirements Remote power control requirementsRemote support connection requirements 155 156 DS8000 Series Concepts and Architecture 157 Configuration planningStorage Hardware Management Console S-HMC Configuration planning overviewExternal S-HMC S-HMC and Ethernet switchesDS Storage Manager Remote servicesHMC software components Required ports 161HMC network topology 163 Dial-up connectionSecure high-speed connection Call home Remote access165 HMC security considerationsSecurity mechanism 1 Console must initiate session Security mechanism 2 Public key encryptionHMC user management Security mechanism 3 Login securityFTP Offload option 167 Operating environment license OEL required featureLicensed function indicators DS8000 licensed functionsLicense scope for each DS8000 licensed function Optional featuresOperating environment license feature codes Point-in-Time Copy function 2244 Model PTCRemote Mirror for z/OS 2244 Model RMZ Point-in-Time Copy PTC feature codesRemote Mirror and Copy RMC feature codes Remote Mirror and Copy functions 2244 Model RMCOrdering licensed functions Parallel Access Volumes 2244 Model PAVRemote Mirror for zSeries RMZ feature codes Parallel Access Volumes PAV feature codesUser authorize to FlashCopy 25 TB of CKD data 171Solution 173 Disk storage feature activationAdding storage capacity to an existing licensed function Logical configurationsCapacity planning Scenarios for managing licensingCKD RAID rank capacity 175FB RAID rank capacity Sparing rules177 Sparing examplesSparing Example 2 RAID-10 11 Sparing example 3 RAID-5 Different capacity, same RPM 179IBM Standby Capacity on Demand Standby CoD Sparing Example 4 RAID-5181 Capacity and well-balanced configurationDDM to DA Mapping -- 2-way 183 Data migration planningRemote copy technologies Basic commandsOperating system mirroring Software packages185 Migration services and appliances6 z/OS data migration methods 15 Different data migration methods Planning for performanceNumber of host ports/channels Parallel Access Volumes z/OS onlyDisk Magic Size of cache storageHot spot avoidance 189 DS Storage Manager logical configurationStorage configuration terminology Configuration hierarchy, terminology, and conceptsPSeries1 PSeries2 Extent pools Array sitesArrays RanksExtent Pool Volume groups Logical volumesVolume Group Address groups Host System CExtent Pool Extent Pool Planning Array layer Raw or physical DDM layerArray site layer Extent pool layer Logical Configuration flowLogical volume layer Rank layerConnecting to the DS8000 Introducing the GUI and logical configuration panelsWelcome panel 10 Entering the URL using the TCP/IP address for the S-HMC12 The Welcome panel Real-time Manager configurationSimulated Manager configuration Copy ServicesLog Creating and defining the users and passwords15 User administration panel Using the help panels information center17 View of the information center Navigating the GUI20 View of the Storage Complexes section 19 View of the storage complexes in the work area21 Storage unit view of the pull-down Radio buttons and check boxesConfiguring a storage complex Logical configuration processConfiguring the storage unit 25 The General storage unit information panel Configuration advancement steps 28 Specify I/O adapter configuration panel 29 Create host systems, screen Configuring the logical host systems31 View of the General host information panel 33 Define host ports panel, with updated host information Click Apply assignment and OK Creating arrays from array sites36 The Definition method panel 38 The Add arrays to ranks panel with FB selected Creating extent pools39 The Definition method panel Creating FB volumes from extents41 The Select extent pool panel 42 The Define volume properties panelClick Volume Groups Creating volume groups44 The Define volume group properties filled out Click Host Systems Deleting LUNs and recovering space in the extent poolAssigning LUNs to the hosts Click Finish Creating CKD volumesClick Volumes → zSeries Creating CKD LCUsClick Storage Units Displaying the storage unit Wwnn49 View of the Wwnn in the General panel 230 DS8000 Series Concepts and Architecture 231 Functionality IntroductionSupported environments Installation methodsESS Copy Services command flow using ESS Copy Services CLI Command flowTCP/IP ports DS CLI command flowSecure sockets DS8000 split network DS6000 command flowESS CLI co-existence Command flow for the DS6000CLI co-existence Storage managementUser security Command modesSingle command mode Example 11-1 Using DS CLI via a single commandExample 11-3 Creating a DS CLI script Interactive modeScript mode Example 11-4 Using DS CLI in interactive modeUser assistance Lists all available DS CLI commandsLists all DS CLI commands with syntax information Syntax conventionsDS CLI return codes Example 11-8 Use of the help -lcommandReturn codes Man pagesExample 11-10 Return code examples Example 11-11 Example of a configuration scriptUsage examples Mixed device environments and migration Which CLI to use based on what hardware you have installedMigration considerations DS CLI migration exampleMigration tasks Determining the saved tasks to be migratedCollecting the task details A portion of the tasks listed by using the GUIUsing the GUI to get the contents of a FlashCopy task Converting the saved task to a DS CLI commandConverting a FlashCopy task to DS CLI Example 11-14 Using interactive dscli mode without profilesCreating a user ID for use only with ESS Using DS CLI commands via a single command or scriptProcedure to create an encrypted password file Setting up a profileExample 11-18 Establishing a FlashCopy with a single command Issuing a DS CLI command and scripting itExample 11-19 Creating an executable file Example 11-20 Using script mode252 DS8000 Series Concepts and Architecture 253 Performance considerationsNew and enhanced functions What is the challenge?Speed gap between server and disk storage 255 Where do we start?Pprc over Fibre Channel links Switch from Escon to Ficon portsSSA backend interconnection Arrays across loopsHow the DS8000 series overcomes FC-AL shortcomings Fibre Channel switched disk interconnection at the back endHow does the DS8000 address the challenge? FC-AL shortcomingsMemory 259 New four-port host adapters Fibre Channel device adapter261 POWER5 Heart of the DS8000 dual cluster designRIO-G Interconnect 263 RIO-G InterconnectVertical growth and scalability Performance and sizing considerations for open systems265 Workload characteristicsData placement in the DS8000 Cache size considerations for open systems266 DS8000 Series Concepts and Architecture LVM striping267 Stripe sizeSubsystem Device Driver SDD Dynamic I/O load-balancing Determining where to attach the hostDetermining the number of paths to a LUN 269 Performance and sizing considerations for z/OSConnect to zSeries hosts 12 DS8100 frontend connectivity example partial view Performance potential in z/OS environments271 Appropriate DS8000 size in z/OS environmentsProcessor memory size considerations for z/OS environments Or zSeries channel consolidation 273 Disk array sizing considerations for z/OS environmentsConfigure one extent pool for each single rank Configuration recommendations for z/OS275 Minimize the number of extent poolsPlan for a reasonable number of extent pools Extent pool0 Extent pool115 Mix of extent pools 277278 DS8000 Series Concepts and Architecture 279 280 DS8000 Series Concepts and Architecture 281 ZSeries software enhancementsScalability support Software enhancements for the DS800013.2 z/OS enhancements 283 Large Volume Support LVSRead availability mask support Benefits of the scalability enhancementsRead control unit and device recognition for DS8000 Initial Program Load IPL enhancements13.2.5 DS8000 definition to host software 285 New performance statisticsListdata Count Listdata Counts report of DS8000 287Listdata Status 289 Resource Management Facility RMFCoexistence considerations 13.3 z/VM enhancements13.4 z/VSE enhancements Migration considerations291 TPF enhancements292 DS8000 Series Concepts and Architecture 293 Data migration in zSeries environmentsConsolidate storage subsystems Define migration objectives in z/OS environments295 Consolidate logical volumesConsiderations for new logical volume size Example 14-1 Data Classes with EF attribute Dynamic Parallel Access Volumes required for large volumes297 Keep source and target volume size at the current sizePhysical migration with DFSMSdss and other storage software Data migration based on physical migrationSummary of data migration objectives 299 Software- and hardware-based data migrationData migration with Piper for z/OS Piper hardware 301 Data migration with z/OS Global MirrorBridge from Escon to Ficon with Metro/Global Copy Hardware- or microcode-based migration303 Data migration with Metro Mirror or Global CopyPprcopy DDNAMEDD02 Query Example 14-3 All data is replicated 305Example 14-5 All data is replicated 491307 Data Set Services UtilityData migration based on logical migration System utilities Hierarchical Storage Manager, DFSMShsmSMS Storage Groups migration source environment 309Storage Group Application Selection Example 14-8 Select SMS storage group in Scds311 Alter Volume Statuses Pool Copy Pool Backup onlyALL Volumes Altered Example 14-12 Confirmation about SMS volume status change313 Combine physical and logical data migration 315 14.5 z/VM and VSE/ESA data migrationSummary of data migration 316 DS8000 Series Concepts and Architecture 317 318 DS8000 Series Concepts and Architecture 319 Open systems support and softwareSupported operating systems and servers Where to look for updated and detailed informationOpen systems support TotalStorage Proven program DS8000 Interoperability MatrixIBM HBA Search Tool DS8000 Host Systems Attachment GuideAtto Differences to the ESSPlatform and operating system vendors’ pages Emulex CorporationAdditional supported configurations RPQ Boot supportSubsystem Device Driver DS CLI Other multipathing solutionsIBM TotalStorage Productivity Center IBM TotalStorage Productivity CenterMDM main panel Sample Device Manager view Device ManagerSample screenshot of TPC for Disk TPC for DiskTPC for Replication Global Mirror UtilityEnterprise Remote Copy Management Facility eRCMF 332 DS8000 Series Concepts and Architecture 333 Data migration in the open Systems environmentTor Host operating system-based migration Comparison of migration methodsCopy raw devices Basic copy commandsOnline copy and synchronization with rsync Migration using volume management softwareMigration using LVM mirroring Backup and restoreSubsystem-based data migration Migration using backup and restoreCombination of Metro Mirror and Global Copy Metro Mirror and Global CopyPiper migration IBM Piper migrationOther migration applications IBM migration services343 Appendix A. Open systems operating systems specificsCapacity planning considerations Data placement considerationsDS8000 Host Systems Attachment Guide PlanningExample A-1 AIX iostat output Unix performance monitoring toolsIostat Example A-2 SUN Solaris iostat output System Activity Report SARExample A-3 SAR Sample Output VmstatExample A-4 Finding Fibre Channel adapter WWN Other publicationsAIX host attachment scripts Finding the World Wide Port NamesSubsystem device driver SDD Determine the installed SDD levelUseful SDD commands Managing multiple pathsMultipath I/O Mpio Example A-7 lsvpcfg commandExample A-8 lspath command result Determine the installed Sddpcm levelUseful Mpio commands LVM mirroring LVM configurationAIX access methods for I/O LVM stripingConcurrent I/O Boot device supportAIX on IBM iSeries Direct I/OExample A-9 Filemon output file Monitoring I/O performanceIostat FilemonIBM Mpio FC Linux Getting Started with zSeries Fibre Channel Protocol Existing reference materialImplementing Linux with IBM Disk Storage Linux with zSeries and ESS EssentialsTable A-1 Major numbers and special device files Important Linux issuesSome Linux Scsi basics Example A-10 Create new special device files for Scsi disks Missing device filesScsi device assignment changes Managing multiple pathsLimited number of Scsi devices Fibre Channel disks discovered before internal Scsi disks RedHat Enterprise Linux RH-EL multiple LUN supportExample A-13 SCSi disks attached at system start time Adding FC disks dynamicallyExample A-12 Sample /etc/modules.conf Gaps in the LUN sequence Linux on IBM iSeriesExample A-16 Sample /proc/scsi/scsi file Troubleshooting and monitoring/proc pseudo file system Example A-17 Sample /proc/scsi/qla2300/x Performance monitoring with iostatGeneric Scsi tools SDD for Windows HBA and operating system settingsMicrosoft Windows 2000/2003 Figure A-1 Microsoft VDS Architecture Windows Server 2003 VDS supportGeographically Dispersed Sites FC port configurationVolume Shadow Copy Service HP OpenVMSConfigurations Volume configurationOpenVMS volume shadowing Command Console LUNAppendix A. Open systems operating systems specifics 372 DS8000 Series Concepts and Architecture 373 Appendix B. Using DS8000 with iSeriesHardware Logical volume sizesTable B-1 OS/400 logical volume sizes Supported environmentChanging LUN protection Protected versus unprotected volumesUsing 5250 interface Adding volumes to iSeries configurationFigure B-3 Work with Disk Configuration menu Figure B-5 Confirm Add Units Adding volumes to an Independent Auxiliary Storage PoolFigure B-7 iSeries Navigator Signon to iSeries window Figure B-9 SST Signon Figure B-11 New disk pool welcome Figure B-13 Confirm disk pool configuration Figure B-15 Choose the disks to add to the Disk Pool Figure B-17 New Disk Pool Summary Figure B-20 New Disk Pool shown on iSeries Navigator Avoiding single points of failure MultipathFigure B-22 Single points of failure Configuring multipathFigure B-24 Example of multipath with iSeries Adding multipath volumes to iSeries using 5250 interfaceFigure B-25 Adding multipath volumes to an ASP Figure B-27 Adding a multipath volume Adding volumes to iSeries using iSeries NavigatorFigure B-28 New Disk Pool shown on iSeries Navigator Figure B-30 Example of multipath logical units Managing multipath volumes using iSeries NavigatorAppendix B. Using DS8000 with iSeries Figure B-32 Multipath logical unit properties Figure B-33 Multipath connections Multipath rules for multiple iSeries systems or partitionsChanging from single path to multipath Sizing guidelinesCache Planning for arrays and DDMsTable B-2 Capacity per I/O Adapter Number of iSeries Fibre Channel adaptersSize and number of LUNs Table B-3 Disk operations per second per RAID rank Recommended number of ranksSharing ranks between iSeries and other servers Metro Mirror and Global Copy Connecting via SAN switchesMigration OS/400 mirroringOS/400 data migration Figure B-35 Using Metro Mirror to migrate from ESS to DS8000Figure B-36 Ending allocation for existing disk units Remote Mirror and Copy Copy Services for iSeriesFlashCopy AIX on IBM iSeries ISeries toolkit for Copy ServicesLinux on IBM iSeries 406 DS8000 Series Concepts and Architecture 407 Appendix C. Service and support offeringsIBM Implementation Services for TotalStorage Copy Functions IBM Web sites for service offeringsIBM service offerings IBM Implementation Services for TotalStorage disk systemsEnterprise Remote Copy Management Facility eRCMF IBM Geographically Dispersed Parallel Sysplex GdpsIBM eServer iSeries Copy Services IBM Operational Support Services Support LineAppendix C. Service and support offerings 412 DS8000 Series Concepts and Architecture 413 IBM RedbooksOther publications Online resources Help from IBM How to get IBM Redbooks416 DS8000 Series Concepts and Architecture 417 IndexDS CLI OEL Escon Ficon RH-EL BBU Spcn VSE IBM TotalStorage DS8000 Series Concepts and Architecture Page Page IBM TotalStorage DS8000 Series Concepts Architecture
Related manuals
Manual 78 pages 25.99 Kb Manual 374 pages 22.96 Kb