Power Supply Specifications
Power Supply Specifications
Table 2 lists and describes the electrical specifications for the 750 W
Table 2 | Electrical Specifications, 750 W | |
|
|
|
Specification |
| Description |
|
|
|
| Autoranging input with power factor correction | |
|
| (PFC) |
|
| |
100 to 240 VAC (115/230 VAC nominal) | ||
|
| |
|
| |
• 11 A @ 100 VAC (max) | ||
|
| • 6 A @ 200 VAC (max) |
|
| |
47 to 63 Hz (50/60 Hz nominal) | ||
|
| |
Branch circuit requirement | Each chassis power supply should have its own | |
|
| dedicated, |
|
| • For North |
|
| • For |
|
| local and national codes |
|
| • All AC power supply inputs are fully isolated. |
|
| • Source AC can be out of phase between |
|
| multiple power supplies in the same chassis, |
|
| which means that PS1 can be operating from |
|
| phase A and PS2 can be operating from |
|
| phase B. |
|
| |
Power supply output capacity | 750 W | |
|
| |
Power supply output | • 12 VDC @ 62 A | |
|
| • 3.3 VDC @ 3 A |
|
| |
Output holdup time | 16 ms minimum (20 ms @ 60% load) | |
|
| |
BTU (total output)1 | 1122 BTU/hour (nominal) | |
|
| 1365 BTU/hour (max) |
|
| |
1. 1000 BTU/hour = 293 W |
|
Catalyst
| 13 |
| |
|
|