Remote End Testing
If you have a second test tool or a smart remote, you can perform remote end testing. The remote end testing feature allows you to run the
When you enable remote testing the NEXT@REMOTE and ACR@REMOTE tests appear in the AUTOTEST and SINGLE TEST modes if the selected test standard requires the tests. Model
Selecting Auto Detect allows the test tool to identify the remote as a standard or smart remote and run the REMOTE tests as appropriate.
To enable remote end testing, proceed as follows:
1.Turn the rotary switch on the main unit to SETUP.
2.Use Dto highlight the remote end testing status.
3.Press ! Choice.
4.Use Uto highlight Enable or Auto Detect; then press E
If you use a
SMART REMOTE READY: The remote unit is waiting for the main unit to start a test.
SMART REMOTE TESTING: The main unit is running a test.
SMART REMOTE PASS or FAIL: Pass or fail is the overall result of the test just completed. This message is displayed for about 3 seconds after a test is completed.
SMART REMOTE READY
PREVIOUS TEST: PASS or PREVIOUS TEST: FAIL: The remote is waiting for the main unit to start another test. Pass or fail is the overall result of the previous test.