Maintenance and Specifications 8

Specifications

Length Test

Table 8-4 shows the specifications for the length test.

Table 8-4. Length Test Specifications

Range

Resolution

Accuracy

Range

Resolution

Accuracy

Twisted Pair cable

0 to 328 ft (100m)

1 ft or 0.1m

±(1 ft (.3m) + 2% of reading) 328 to 2500 ft (762m)

1ft or 0.1m

±(1 ft (.3m) + 4% of reading)

Coax

0 to 328 ft (100m)

1 ft or 0.1m

±(1 ft (.3m) + 2% of reading) 328 to 4000 ft (1219m)

1ft or 0.1m

±(1 ft (.3m) + 4% of reading)

Note

Specifications are relative to calibrated value using a representative reference cable. Variations occur because of variations in the cable manufacturing process.

Propagation Delay Test

Table 8-5 shows the specifications for the propagation delay test.

Table 8-5. Propagation Delay Test Specifications

Range

Resolution

Accuracy

Range

Resolution

Accuracy

Twisted Pair cable

0 to 500 ns

1 ns

±(2 ns + 2% of reading)

500 to 3800 ns

1 ns

±(2 ns + 4% of reading)

Coax

0 to 500 ns

1 ns

±(2 ns + 2% of reading)

500 to 6000 ns

1 ns

±(2 ns + 4% of reading)