Impulse Noise
Adjustable from 100 mV to 500 mV in 10 mV steps. The default threshold is 270 mV.
Monitors either polarity of noise on pair 3, 6.
Minimum detectable impulse width: 10 ns
Model DSP-100 LAN Traffic
Monitors 10 Mb/s Ethernet only; UTP or coaxial cable.
Monitors pair 3, 6 for either polarity of data.
Generates a positive polarity link pulse on pair 1, 2.
Model DSP-2000 LAN Traffic
Monitors 10BaseT traffic using the MONITOR RJ45 jack. Monitors pair 3, 6 for either polarity of traffic. Generates a positive polarity link pulse on pair 1,2.
Monitors 100BaseTX traffic Ethernet traffic using the MONITOR RJ45 jack. Monitors pair 3, 6 for either polarity of traffic. Generates 100BaseTX link signals on pair 1, 2.
Monitors 10 Mb/s Ethernet traffic using the COAX jack with the RJ45 to BNC adapter provided.
Serial Interface
Connector: DB9 (DTE male)
Baud rate: 1200 to 38,400 baud
Flow control: hardware, XON/XOFF, or none
Data format: 8 data bits, 1 stop bit, no parity